3.5.10 Mounting the chimney
The chimney comprises two chimney ducts that slide inside
one another. There are two ventilation slots inside the inner
chimney duct.
ATTENTION!
Danger of damage through improper handling
The body of the hood and the chimney could be damaged
by movements during the installation.
☞
Keep a distance between the chimney and the body of
the hood.
☞
Keep objects that could scratch the device far away from
it (e.g. tools, belt buckles).
The chimney ducts are aligned with one another depending
on the operating mode.
Recirculating mode and hybrid mode
The ventilation slots are located at the top and are not
covered.
Extracted air mode
The inner chimney duct can be drawn out and re-inserted
upside-down in order to cover the ventilation slots.
1.
2.
☞
Lift the chimney up with two persons.
☞
Place the lower edge of the chimney into the groove of
the device.
☞
Pivot the chimney flush against the wall.
☞
Pull the inner chimney duct upwards.
☞
Hang the inner chimney duct up on the chimney mount.