98
Operation
6002644_0 – 20.01.2016
4.3.1
Run-on function
The device comes with a run-on function. If this function is
used, the device will work for a further ten minutes at the last
chosen power level.
In recirculating mode, it is necessary to use the run-on
function so that the device can remove the remaining
odours. Using the run-on function increases the life of the
filter filling. The filter filling must be replaced at regular
intervals.
The run-on function can be switched on manually or
automatically. The automatic run-on function is activated in
configuration mode.
D
“4.4 Configuration” (page 99).
Touch
field
Function
The device is switched on.
If the automatic run-on function is activated:
☞
Touch the touch field 1x.
The device switches off.
The run-on time starts automatically in the last
selected power level.
If the automatic run-on function is not
activated:
☞
Touch the touch field 2x - within 2 seconds.
The device switches off.
The run-on time is started manually in the last
selected power level.
During the run-on time (10 minutes), the
operating symbol for the selected power level
will flash.
4.3.2
Extraction mode / recirculated air mode
changeover
If the device is configured for hybrid mode, it is possible to
switch between extraction mode and recirculated air mode
at any time after activating the changeover function.
The changeover function is activated in configuration mode.
D
“4.4 Configuration” (page 99).
Touch
field
Function
If the changeover function is activated:
☞
Touch the touch field 1x.
Touch field illuminates dimly.
The device operates in exhausted air mode.
The wall box is opened.
The cleaned air is discharged outside.
Touch field illuminates brightly:
The device is operating in recirculated air
mode.
The wall box is closed.
The cleaned air is discharged into the room.
4.3.3
Check filter filling indicator
The device has a check indicator in order to remind the
operator to change the filter filling. In recirculating air mode,
the check indicator flashes every 350 hours of operation.
The hours counter is started anew by switching off the check
indicator.
The check indicator is switched off in configuration mode.
D
“4.4 Configuration” (page 99).
Touch
field
Function
Touch field flashes:
The filter filling must be replaced.
D
“6.2.2 Replacing filter filing (with
recirculating and hybrid mode)”
(page 102).