Installation instructions
Installation instructions
27
Installation instructions
Description for the installer
Possible operating modes
The following illustrations show the way the
possible operating modes work. The devices
used are shown as symbols. The illustrations are
meant to serve as a guide. The illustrated device
shapes may differ from your device.
The device can be fitted in different operating modes:
§
Recirculated air mode
§
Extracted air mode
§
Hybrid mode
Depending on the desired operating mode, the
installation of the device varies. The different
installations of the individual operating modes are
described in the following sections.
Ø
Make sure that all safety instructions and
regulations are adhered to during installation.
Installation for recirculated air mode
In this installation a BUF recirculated air filter is fitted to
the device's fan outlet.
Ø
Make sure that the cross-section of the ventilation
slits in the top structure is more than 300 cm².
Ø
Make sure that the air can flow freely out of the
device.
Ø
Ensure that you can change the filter filling at a
later date.
The filter's filling needs to be regularly replaced.
Installation for extracted air mode
Observe and follow the information concerning
the exhaust pipe in the Information about
extracted air mode chapter.
In this installation the exhaust pipe is fitted to the
device's fan outlet.
Ø
Make sure that the exhaust pipe has a diameter of
at least 125 mm.
Ø
Make sure that the air can flow freely out of the
device.
Summary of Contents for BLB 60 FL
Page 63: ...Contact 63 ...