Installing the device
54
Installation instructions
Ø
Tighten the screw of terminal 1.
Ø
Connect the cable wire 2 in the same way to the
"Fensterschalter" terminal 2.
The control cable for the window contact switch is now
connected.
Creating the exhaust air connection
You can install the device for different operating
modes:
§
Recirculated air mode
§
Extracted air mode
§
Hybrid mode
The installation for the individual operating modes is
described in the following sections.
Installing the device for recirculated air mode
WARNING
Risk of falling when changing the filter
or during work carried out at height.
Ø
Use a stable step-ladder.
CAUTION
Risk of injury from falling parts.
Ø
Ensure that no-one is underneath
the device while working.
ATTENTION
Damage caused by falling parts.
Ø
Protect areas and devices (e.g.
cooled cooking hob) underneath the
working area against damage, e.g.
using a thick piece of cardboard.
To make sure that the filter are installed correctly,
a guide is fitted to the device's filter seating.
The filter is inserted correctly when the bottom edge of
the filter is parallel to the top edge of the fan's housing
and the gap is approximately 5 mm wide.
Ø
Insert the recirculated air filter from the top onto the
guide of the fan housing.
Ø
Make sure that the filter is fitted correctly.
Summary of Contents for BLB 60 FL
Page 63: ...Contact 63 ...