37
Installation
EN
6003850_0 – 01.12.2017
Depending on the installation situation,
accessories may be connected to the
hood:
y
Wall box
y
Recirculated air filter permalyt
y
Window contact switch
y
Under-pressure monitor
Observe the instructions for the
accessories.
12 V DC
4
5
6
7
BMK-F
F-K
2
3
1
D
A
B
C
E
F
G
H
12 V DC
GND
X1
X1
X1
+
5 V
MFK
MFK
BMK2
BMK1
ST3
+
+
–
–
I
y
1 - 4 = Accessories (e.g. wall box,
window contact switch)
y
5 - 7 = Only for use with berbel
control flap (5 = GND, 6 = 24 V DC,
7 = 24 V DC switched)
A Control box
y
BMK1: Wall sleeve contact,
optocoupler collector,
max. 12 mA / 12 V DC, safe
galvanic separated
y
BMK2: Wall sleeve contact,
optocoupler emitter,
max. 12 mA / 12 V DC, safe
galvanic separated
B Terminal “BMK-F” for the wall box
connection
C Terminal “F-K” (multifunction contact)
for the window contact switch or
under-pressure monitor connection
D Control line from the wall box
E Wall box
F Wall box power unit
G Window contact switch
H Control line from the window contact
switch
I Control flap connection