10
Installation
6004977_a – 28.02.2020
3.
Installation
3.1
Safety instructions for installation
D
WARNING!
Hazard through disregard of the installation instructions!
This chapter contains important information for the safe
installation of the device.
☞
Read through this chapter carefully before installing the
device.
☞
Follow the safety instructions.
☞
Carry out the installation as described.
y
Installation only by qualified specialist personnel.
D
“1.2 Authorised target groups” (page 4).
y
Electrical work must only be undertaken by qualified
electricians.
D
“1.2 Authorised target groups” (page 4).
y
The hob and other parts that can be touched must be
allowed to cool prior to installation.
y
Store the film or other parts of the packaging in a location
which is inaccessible to children.
y
The device must be in an undamaged and fault-free
condition prior to installation.
y
Cables must not be kinked, crushed or damaged.
y
Never open the fan housing.
y
The power supply voltage must match the voltage
information quoted on the ratings plate.
D
“2.6 Technical data” (page 9).
y
Ensure that the power supply is stable and remains so
prior to the installation.
Connect the power supply only when instructed to do so
in the installation instructions.
3.2
Requirements for the installation location
D
WARNING!
Risk of death due to improper installation!
Disregard of the ambient conditions can lead to hazardous
situations, e.g. in the handling of electrical power or gas.
☞
Make sure that the requirements for the installation
location are complied with.
y
Do not install in potentially explosive atmospheres.
y
With simultaneous use of a heating point which uses air
from the room as its oxygen supply (e.g. chimneys):
y
A safety device is absolutely essential.
y
The safety device must prevent gases being drawing
to the room.
y
An approval for commissioning (e.g. from a chimney
sweep) must be available.
y
If it is necessary to break through the wall:
A wall break-through influences the structural integrity
of the building. This work must only be carried out by a
specialist.
y
Make sure that the building electrical supply is properly
earthed.
y
The power supply voltage present must match the
voltage information quoted on the ratings plate.
y
The customer must supply a means of connection to the
voltage supply in the installation area.
y
An all-pole isolating device (with a contact gap of at least
3 mm) must be provided.
y
Use of an extension cable for connection to the voltage
supply is not permitted.
y
The hob must only be installed next to cabinets or walls
on one side in accordance with Type Y protection against
the risk of fire. Furniture or devices on the other side must
not be higher than the hob.
y
The distance from the hob to a wall or furniture must be
at least 40 mm.
y
The device must not be installed above the following
devices:
y
Oven without fan
y
Dishwasher
y
Clothes dryer
y
The work top must be installed with heat-resistant
adhesive (75 °C), sealed with special paint, silicone rubber
or cast resin.
y
Wall trim used in conjunction with installation must be
heat-resistant.
y
The device must be installed in a lower cabinet with a
minimum width of 900 mm. If a recirculated air filter is
installed under the lower cabinet, the base height must
be at least 100 mm.
y
The device must remain accessible at all times for
maintenance work (e. g. with a removable rear panel or
service cover). The space must be sufficiently large to
allow for removal of the recirculated air filter.
Summary of Contents for Downline BKF 83 DL-A
Page 40: ...6004977_a 28 02 2020 ...