13
Installation
6004977_a – 28.02.2020
EN
3.5.3
Check the dimensions
To determine the dimensions of the hob, refer to the
order documents.
Flush installation
a
b
x
z
y
≥ 37
Cutaway
Width (a)
810 + 2 mm
Depth (b)
485 + 2 mm
Corner radius
R3
Milled recess
Width (x)
13 mm
Height (y)
5 mm
Outer dimensions
836 x 511 mm
Corner radius
R6
Work top
Height (z)
> 10 mm
Counter-top installation
z
a
b
≥ 50
Cutaway
Width (a)
810 + 2 mm
Depth (b)
485 + 2 mm
Work top
Height (z)
> 10 mm
☞
Check the dimensions.
D
“2.6 Technical data” (page 9).
☞
Ensure that the work top is suitable for the hob
installation.
B
A
☞
Check the spatial conditions for your installation variant.
A If necessary due to spatial conditions, (e.g. with large
lower cabinets), shallow duct sections can be installed
between the opening on the fan housing and the duct
bend.
B If necessary due to spatial conditions, (e.g. with a short
distance from the wall), the duct bends must be attached
to the fan housing before the hob is installed.
Summary of Contents for Downline BKF 83 DL-A