4.3.1
Automatic rapid heat-up function
All four cooking zones are equipped with automatic heat-up
boiling. When activated, the selected cooking zone heats
up with maximum power and then switches to the desired
power level.
Button
Function
☞
Choose the desired cooking zone.
☞
Press and hold the desired power level on
the slider for 3 seconds.
y
This indicator and the selected power level
blink alternatingly.
y
After the end of the rapid heat-up time,
the cooking level switches to the desired
power level.
y
With selection of a lower power level, the
automatic rapid heat-up is switched off.
4.3.2
Pause function
Function for interruption of a cooking process with saved
settings. Access takes place after pressing the menu button;
the corresponding symbol is displayed.
Button
Function
☞
Press the slider at the position below the
symbol.
y
The cooking process is interrupted.
y
The adjusted values are saved and
reactivated when pressed again.
4.3.3
Recall function
Function for restoring the settings used most recently.
The following values are saved for 6 seconds after switching
off the device:
y
Cooking zone power levels
y
Cooking zone timer settings.
y
Automatic rapid heat-up settings
y
Simmering level settings
Button
Function
The symbol blinks for 6 seconds.
☞
Press the slider at the appropriate position
before the symbol stops blinking.
y
The adjusted values are reactivated.
4.3.4
Cleaning function
In order to prevent undesired use of the device during
cleaning, the control panel can be locked temporarily.
Access takes place after pressing the menu button;
the corresponding symbol is displayed.
Button
Function
☞
Press the slider at the position below the
symbol.
y
The control panel is locked for 20 seconds;
only the On/Off button remains active.
y
The timer displays the countdown.
Summary of Contents for Downline BKF 83 DL-A