3.5.7
Install exhaust air kit DL
Installation variant for extracted air mode.
By trimming, it is possible to align the shallow duct with the
spacing between the connections:
y
Between the fan housing and conduit bend with deep
base cabinets.
y
Between the conduit bend and elbow duct with high
base cabinets.
x
☞
Cut the appropriate shallow duct sections. The quantity
and length must be adapted to the installation variant.
For the following steps, the adaptors of the air-carrying
components (e.g. conduit bend, shallow duct sections) must
be sealed with sealing strip after they have been fit together.
☞
Insert the conduit bend in the connection on the fan
housing.
☞
Insert the elbow duct in the conduit bend.
The routeing of the exhaust line takes place via a suitable
shallow duct system (not included in the scope of delivery).
☞
Ensure that the exhaust air duct is correctly fitted.
☞
Adhere sealing strip to the adapters.