8
Installation
6005437_a – 30.05.2022
3.
Installation
3.1
Safety instructions for installation
D
WARNING!
Hazard through disregard of the installation instructions!
This chapter contains important information for the safe
installation of the device.
☞
Read through this chapter carefully before installing the
device.
☞
Follow the safety instructions.
☞
Carry out the installation as described.
y
Installation only by qualified specialist personnel.
D
“1.2 Authorised target groups” (page 4).
y
Electrical work only to be undertaken by qualified
electricians.
D
“1.2 Authorised target groups” (page 4).
y
At least three persons are required for the installation.
y
When working at heights, ensure good stable footing
(e.g. stable stepladder).
y
The hob and other parts that can be touched must be
allowed to cool prior to installation.
y
Store the film or other parts of the packaging in a location
which is inaccessible to children.
y
The device must be in an undamaged and fault-free
condition prior to installation.
y
Cables must not be kinked, crushed or damaged.
y
Never open the fan housing.
y
It is not permissible to attach further components
(e.g. panels, air ducts) to the device.
y
The power supply voltage must match the voltage
information quoted on the ratings plate.
D
“2.5 Technical data” (page 7).
y
Ensure that the power supply is stable and remains so
prior to the installation.
Connect the power supply only when instructed to do so
in the installation instructions.
3.2
Requirements for the installation location
D
WARNING!
Risk of death due to improper installation!
Disregard of the ambient conditions can lead to hazardous
situations, e.g. in the handling of electrical power or gas.
☞
Make sure that the requirements for the installation
location are complied with.
y
Do not install in potentially explosive atmospheres.
y
With simultaneous use of a heating point which uses air
from the room as its oxygen supply (e.g. chimneys):
y
A safety device is absolutely essential.
y
The safety device must prevent gases being drawing
to the room.
y
It is essential to ensure that the negative pressure
in the heating point installation room does not
exceed 4 Pa.
y
An approval for commissioning (e.g. from a
chimneysweep) must be available.
y
Installation is only permitted on structural building
elements capable of bearing the load (solid structure).
y
If installed above a fireplace that uses solid fuels (e.g. coal
stove):
The fireplace must have a sealed cover which cannot be
removed. Otherwise there is a fire risk due to flying sparks.
Applicable legal and country-specific regulations must be
observed.
y
The air flowing out must be able to dissipate unimpeded.
Do not impede the air flow, e.g. through the installation of
objects on or above the device.
y
Make sure that the building electrical supply is properly
earthed.
y
The power supply voltage present must match the
voltage information quoted on the ratings plate.
y
An all-pole isolating device (with a contact gap of at least
3 mm) must be provided for the power supply on the
installation side.
y
There must be a means of connecting the ceiling console
to the power in the installation area.
Country-specific, legal provisions must be observed.
3.3
Requirements for recirculated air mode
y
Recirculated air filter at the fan outlet.
y
Filter filling freely accessible for changing.
Summary of Contents for Skyline Round BIH 60 SKR
Page 26: ...26 6005437_a 30 05 2022 ...
Page 27: ...27 6005437_a 30 05 2022 ...
Page 28: ...6005437_a 30 05 2022 ...