21
Maintenance
6005437_a – 30.05.2022
EN
6.3
Fault rectification
Possible faults are described below:
Description of the fault.
y
Possible cause.
☞
Remedy.
Fan and lighting do not work.
y
No power supply.
☞
Check that the all-pole mains switch is connected.
☞
Switch the mains switch on.
y
The breaker may have been tripped or is defective.
☞
Check to see if the breaker has tripped.
☞
If you use electric circuit breakers, turn the circuit
breaker on again.
☞
For other types of fuse, consult a qualified electrician.
The fan does not work.
y
The device is not switched on.
☞
Check all power levels.
y
The device is connected to a window contact switch and
the window is closed.
☞
Open the window.
y
The device is connected to a safety device. The safety
device detects a critical under-pressure.
☞
Open a window.
☞
Wait until the air pressure returns to normal.
The lighting does not work.
y
The device software requires a restart.
☞
Interrupt the power supply for approx. 10 seconds.
y
The lamp has blown.
☞
Please consult your dealer or customer services.
Smells occur during operation.
y
The filter filling is used up.
☞
Change the filter filling.
D
“6.2.2 Replacing filter filling” (page 19).
Poor device performance.
y
The recirculated air filter is clogged.
☞
Replace the filter filling of the recirculated air filter.
D
“6.2.2 Replacing filter filling” (page 19).
The smoke can settle on furniture, the fronts of kitchen units and
the ceiling.
y
Smoke development by heating cooking oils and cooking
fats to too high a temperature.
☞
Note the smoke point of the cooking oil or fat you
are using. You can obtain this information from the
respective manufacturer.
Moisture in the device.
y
Dripping or splashing water has penetrated the device.
y
Liquid (e.g. from vases, bottles on the device) has
penetrated the device.
☞
Immediately shut off the power supply, by removing
the fuse.
☞
Make sure that the power supply cannot be
unintentionally reconnected. For example by tasking
a person with ensuring that the fuse/breaker is not
restored/switched on.
☞
Ensure that no more liquid can penetrate the device.
☞
Allow the device to dry.
☞
Have the device checked and repaired by qualified,
specialist personnel prior to using the device again.
After a power interruption, the “Raise” button flashes on the
remote control.
y
The power supply dropped out whilst the drive motor
was in operation. The device is in calibration mode and
requires a reference run.
☞
Press the “Raise” button on the remote control.
The device moves fully upwards once again and then into
the set top end position.
The “Raise” and “Lower” buttons on the remote control flash but
the device does not move.
y
The safety switch-off took place because a problem was
detected (e.g. faulty winding or tearing of a suspension
rope).
☞
Please consult your dealer or customer services.
The device does not react to inputs on the remote control.
Observe the instruction manual for the remote control.
If a fault persists:
☞
Please consult your dealer or customer services.