Insert the mounting aid centrally in the flue.
☞
Align the mounting aid flush with the underside of the
hood body.
☞
Push the holding clips of the cladding panels into the side
slots on the hood body.
☞
Fold the cladding panels up.
☞
Secure the cladding panels to the flue with a screw.
☞
Remove the mounting aid.
3.5.6
Connecting accessories
Depending on the installation situation, available accessories
may be connected to the hood, e.g.:
y
Wall box
y
Window contact switch
y
Control flap
y
Recirculated air filter permalyt
Observe the instructions for the accessories.
D
ATTENTION!
Danger of damage due to improper connection!
Applied voltage or defective connections can result in
damage to the electronics.
☞
Ensure that the power supply is switched off and remains
so.
☞
Ensure correct assignment of the connections.
☞
Make sure that the accessories plugs are fully inserted.
A B C
A Jack socket - for connection of wall box, control flap or
recirculated air filter permalyt.
B DC power socket - for connecting a window contact
switch.
C Connection socket (RJ45) – BUS interface for connection
with special accessories of the manufacturer.
Connection with a PC or other devices is not permitted.
Wall box
y
The wall box is closed when the control contacts are open.
y
The wall box is open when the control contacts are closed.
Window contact switch
y
The hood‘s fan is only operational when the window is
open.
Safety device
y
The hood‘s fan is only operational when no critical under-
pressure is determined in the room.
☞
Connect any available accessories.
☞
Route the cable such that it is not kinked, crushed or
damaged and so that it will not get in the way when
replacing the filter filling.