background image

8

20117340 - Rev

. 6 (12/17)

 

END USER

13  RECYCLING AND DISPOSAL

The device is primarily composed of:

Material

Component

steel

structural work

PU (polyurethane)

insulation (models 200 - 550)

polystyrene - polyester felt

insulation (models 750 - 1000)

PE (polyethylene)

water connection washers

ABS (acrylonitrile-butadiene-styrene)

lining and covers

At the end of the device's useful life, these components must be separated and disposed of according to current regu-

lations in the country of installation.

END USER INSTRUCTIONS

Refer to the GENERAL SAFETY INFORMATION and PRECAUTIONS section for safety-related information.

14  START-UP

The heater commissioning must be performed by Techni-

cal Assistance Centre personnel.

Under certain circumstances, such as after long periods of 

disuse, the user may need to re-start it without involving the 

Technical Assistance Centre. Before doing so, perform the 

following checks and operations.

-  Check that the supply cocks in the domestic water 

circuit are all open

-  Switch the electricity supply ON at the mains power 

switch and at control panel switch (if fitted).

15  TEMPORARY SHUTDOWN

To reduce to the environmental impact and save energy, 

in case of brief absences, week-ends, short trips, etc., and 

with external temperatures above 0°C, set the heater tem-

perature control, where available, to the minimum value.

If the temperature to which the heater is exposed can 

fall below 0°C (frost hazard), perform the operations 

described in paragraph "Preparing for extended pe-

riods of disuse".

16  PREPARING FOR EXTENDED 

PERIODS OF DISUSE

If the storage cylinder is not going to be used for an ex-

tended period of time, ask the manufacturer’s Technical 

Assistance Centre to make the system safe.

17  EXTERNAL MAINTENANCE

Clean the outside of the storage cylinder with a soft cloth 

damped in soapy water.

Do not use abrasive products, petrol or triethylene.

End user

Via Risorgimento, 23 A

23900 - Lecco (LC), Italy

www.berettaboilers.com

The manufacturer strives to continuously improve all products. Appearance, dimensions, technical 

specifications, standard equipment and accessories are therefore liable to modification without notice.

Summary of Contents for IDRA DS 200 N

Page 1: ...Installation and Operation Manual IDRA DS 200 300 430 550 N IDRA DS 750 1000 N Solar solar storage cylinder IDRA DS N Installation and Operation Manual EN...

Page 2: ...eaks from the storage cylinder turn off the wa ter supply and contact B s Technical Assistance Centre or a qualified heating engineer immediately b If the product is not going to be used for an extend...

Page 3: ...ange is provided for easy cleaning and mainte nance of the anti corrosion magnesium anode 4 IDENTIFICATION The B IDRA DS N solar heaters can be identified by Data plate This lists the technical specif...

Page 4: ...cording to UNI 11300 1 38 1 53 1 67 1 89 2 13 2 33 W K Energy class B B B B B B PERFORMANCE RELATING TO INTEGRATION COIL Upper coil continuous efficiency ACS 10 45 C Vbu reference volume Upper coil de...

Page 5: ...heater pre heated to the indicated temperature considering an increase of the domestic water temperature of 30 C between inlet and outlet according to EN 12897 Temperature of accumulation tank lower...

Page 6: ...h open Apply the upper insulation 2 and the upper cover 5 in order to insert the cover exert a light and ho mogeneous pressure Close the interlocking flaps L completely which were previously left with...

Page 7: ...348 289 289 mm C 403 393 427 443 428 421 mm D 598 693 684 788 799 834 mm E 738 903 824 1088 969 1006 mm F 878 1113 964 1328 1144 1337 mm G 953 1233 1064 1428 1234 1426 mm H 1029 1323 1174 1538 1321 15...

Page 8: ...uit are all open Switch the electricity supply ON at the mains power switch and at control panel switch if fitted 15 TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of...