background image

GENERAL INFORMATION

3

2  PRECAUTIONS

The operation of any appliance that uses electrical power 

demands that a number of fundamental safety precautions 

be respected. In particular:

Never attempt to install the system without using suit-

able personal protection equipment and without fol-

lowing all applicable occupational safety standards.

Do not touch the product when barefoot or wet if it 

has any electrical accessories installed in it.

Never clean or service the storage cylinder without 

first turning the mains power switch OFF to discon-

nect all electrical accessories (if fitted) from the mains 

electricity supply.

Never pull, disconnect, or twist any electrical cables 

coming from the appliance even if it is disconnected 

from the mains electricity supply.

Do not expose the storage cylinder to the elements. It 

is not designed for use outdoors.

Do not allow children or infirm persons to operate the 

system unsupervised.

Do not dispose of packaging material into the envi-

ronment, or leave it within the reach of children, since 

it can become a potential hazard. Dispose of packag-

ing material in compliance with applicable legislation.

3  DESCRIPTION OF THE 

APPLIANCE

The 

B

 

IDRA MS

 boiler produces domestic hot water for 

storage purposes.

Their most important technical features are:

-  the storage cylinder and coil are specially designed 

and shaped for optimum performance in terms of 

stratification, heat exchange and replenishment times

-  internal glazing, bacteriologically inert, to ensure the 

maximum hygiene of treated water, reduce limescale 

deposits and make cleaning operations easier

-  CFC-free polyurethane insulation and an elegant ex-

ternal casing reduce heat loss

-  a  flange  is  provided  for  easy  cleaning  and  mainte-

nance of the anti-corrosion magnesium anode.

4  IDENTIFICATION

The 

B

 

IDRA MS

 solar heaters can be identified by:

Data plate

This lists the technical specifications and performance 

of the product.

BALLON

Modele

Model

Fabrication

Année

bar

W

l

W

kW

l/h

BOLLITORE

Modello

Codice

Matricola

Anno

m

2

kW

T067774IFE

T067774IFE

BOILER

Year

Serial number

V-Hz

Potenza elettrica assorbita

Puissance élect. absorbée

Electrical consumption
Alimentazione elettrica

Alimentat. élect.

Power supply
Dispersioni secondo EN 12897

Déperditions selon EN 12897

Heat loss according to EN 12897

Matricola

Fabrication

Serial number

Modello

Modele

Model

Max pot. assorb.

Puiss. absor. serp.

Power abs. by coil

Code

Code

Massima potenza assorbita  [T° Primario 80°C]

Puissance absorbée serpentin  [T° Primaire 80°C]

Power absorbed by coil  [T° primary 80°C]
Produzione acqua calda sanitaria [∆T 20°C]

Production eau chaude sanitaire [∆T 20°C]

Domestic hot water production [∆T 20°C]

Superficie serpentino 

Surface serpentin 

Coil heat exchange surface area

Press. esercizio max.

Pression service max.

Maximum working pressure of storage cylinder
Capacità del bollitore

Capacité ballon

Storage cylinder capacity

Collegamento di terra obbligatorio - Raccordement a la terre obligatoire

Obligatory ground connection

Beretta Caldaie

Via Risorgimento, 13

23900 Lecco (LC)

Beretta Caldaie

Via Risorgimento, 13

23900 Lecco (LC)

Serial number plate

This specifies the serial number and model.

If these plates or any other means of clearly iden-

tifying the product are defaced, removed or lost, 

proper installation and servicing may be rendered 

difficult.

5  SYSTEM LAYOUT

UAC

EAF

SB

P

M

1

3

6

5

4

2

Storage cylinder

Preset for lifting 

handles (accesso-

ry) and/or device 

grounding point

Coil

Flange for heater 

inspection

Insulation

Cover

P

 Socket

M

 Guide

UAC

  Domestic hot water 

outlet

EAF

  Domestic cold water 

inlet

SB

 Storage  cylinder 

drain

Summary of Contents for IDRA MS 150

Page 1: ...Installation and Operation Manual Storage cylinder IDRA MS Installation and Operation Manual EN ...

Page 2: ... improper installation adjustment maintenance or use b The product must be serviced at least once a year Servicing must be arranged in advance with the B Technical Assistance Centre b All servicing and repairs must be performed by a qualified heating engineer b If water leaks from the storage cylinder turn off the water supply and contact B s Technical Assis tance Centre or a qualified heating eng...

Page 3: ...for easy cleaning and mainte nance of the anti corrosion magnesium anode 4 IDENTIFICATION The B IDRA MS solar heaters can be identified by Data plate This lists the technical specifications and performance of the product BALLON Modele Model Fabrication Année bar W l W kW l h BOLLITORE Modello Codice Matricola Anno m2 kW T067774IFE T067774IFE BOILER Year Serial number V Hz Potenza elettrica assorbi...

Page 4: ...DHW 10 45 C at the different coil inlet temperatures and with the indicated delta T Coil delivery temperature 80 C T 20 C 27 kW 660 l h 70 C T 20 C 19 kW 480 l h 60 C T 10 C 11 kW 280 l h 50 C T 10 C 8 kW 190 l h Set up time required to heat the boiler to 60 C coil probe point reference with primary exchanger at the indi cated delivery temperature and with the indicated delta T Coil delivery tempe...

Page 5: ...oil probe point reference and pri mary exchanger at the indicated delivery temperature considering an increase of the domestic water tempera ture of 30 C between inlet and outlet according to EN 12897 Coil delivery temperature 60 C 223 l Quantity of domestic water obtained in 10 with boiler pre heated to 45 C coil probe point reference and pri mary exchanger at the indicated delivery temperature c...

Page 6: ...NISATION When installing B IDRA MS storage cylinders in old sys tems or systems requiring modernisation always perform the following checks Make sure that the system is fitted with safety and control devices in accordance with applicable legis lation and standards Make sure that the central heating circuit has been flushed out to remove all sludge and lime scale and has been vented and seal tested...

Page 7: ... 33 300 mm DF Flange internal diameter 130 mm A 171 mm B 243 mm C 323 mm D 431 mm E 523 mm F 663 mm G 920 mm H 1088 mm I 604 mm L M8 threaded inserts for grounding point accessory handles connection 700 mm b We recommend that you install isolating valves in the outlet and return lines b Check the efficiency of the seals when filling refilling the storage cylinder b In case of a probe any electric ...

Page 8: ...ricity supply ON at the mains power switch and at control panel switch if fitted 14 TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of brief absences week ends short trips etc and with external temperatures above 0 C set the heater tem perature control where available to the minimum value b If the temperature to which the heater is exposed can fall below 0 C frost ...

Reviews: