GENERAL INFORMATION
5
EMPTYING IN 10’
IDRA MS
150
Quantity of domestic water obtained in 10’ with boiler pre-heated to 60°C (coil probe point reference) and pri-
mary exchanger at the indicated delivery temperature, considering an increase of the domestic water tempera-
ture of 30°C between inlet and outlet (according to EN 12897).
Coil delivery temperature
80°C
272
l
70°C
250
l
Quantity of domestic water obtained in 10’ with boiler pre-heated to 55°C (coil probe point reference) and pri-
mary exchanger at the indicated delivery temperature, considering an increase of the domestic water tempera-
ture of 30°C between inlet and outlet (according to EN 12897).
Coil delivery temperature
60°C
223
l
Quantity of domestic water obtained in 10’ with boiler pre-heated to 45°C (coil probe point reference) and pri-
mary exchanger at the indicated delivery temperature, considering an increase of the domestic water tempera-
ture of 30°C between inlet and outlet (according to EN 12897).
Coil delivery temperature
50°C
170
l
Pressure drops
COIL
PRESSURE DROP (mbar)
800
600
400
1000
200
0
0
1000
2000
3000
4000
FLOW RATE (l/h)