BC360N-BC360NH 

BC370N-BC370NH 

BC500N-BC500NH 

BC650N-BC650NH 

BC1000N-BC1000NH

 

COMMERCIAL ICE MACHINE

 

PLEASE READ CAREFULLY

 

Summary of Contents for BC1000N

Page 1: ...ease contact 1 877 368 2797 FOR SOME MODELS the POWER SUPPLY CORD is NOT INCLUDED MUST HAVE A 3 PRONG GROUNDING PLUG 3355 Enterprise Avenue Suite 160 Fort Lauderdale FL 33331 BC360N BC360NH BC370N BC370NH BC500N BC500NH BC650N BC650NH BC1000N BC1000NH COMMERCIAL ICE MACHINE PLEASE READ CAREFULLY ...

Page 2: ...pes 11 OPERATION Final Checklist before Operation 11 Control Panel Operation 11 12 How the Machine Makes Ice 13 Normal Sounds 13 Preparing the Ice Maker for Long Storage 13 CLEANING AND MAINTENANCE Exterior Cleaning 14 Interior Cleaning 14 Water Distribution Tube Cleaning 15 Ice Making System Cleaning 15 Condenser Cleaning 16 TROUBLESHOOTING GUIDE 17 TROUBLESHOOTING 18 Berg reserves the right to m...

Page 3: ...N means that failure to heed this safety statement may result in minor or moderate personal injury or property or equipment damage All safety messages will alert you to what the potential hazard is tell you how to reduce the chance of injury and let you know what can happen if the instructions are not followed NOTE IMPORTANT SAFETY INSTRUCTIONS WARNING Toreduce the risk of fire electric shockor in...

Page 4: ...e maker Failure to do so can result in back or other injury To ensure proper ventilation for your ice maker the front of the unit must be completely unobstructed Choose a well ventilated area with temperatures above 50ºF 10ºC and below 100ºF 38ºC This unit MUST be installed in an area protected from the elements such as wind rain water spray or drips The ice maker should not be located next to ove...

Page 5: ...her end When moving the ice maker be careful not to damage the power cord Extension Cord Because of potentialsafetyhazards undercertainconditions itis stronglyrecommended thatyou do not use an extension cord with this ice maker Major Features 1 Completely automatic operation 2 Easy read screen Displays operational status reminders and alerts 3 The fan motor responds to the ambient temperature If r...

Page 6: ...or products manufactured by Berg that have been altered in any way including the use of any parts and or other not specifically approved by The Legacy Companies Berg reserves the right to changes and or improvements at any time Specifications and designs are subject to without notice Component Information Top panel Water distribution tube Evaporator Water pump Floater valve Water tank Water curtai...

Page 7: ...nections in accordance with state and localcodes Installation of the ice maker requires a cold water supply inlet of 3 8 9 5 mm soft copper tubing with a shut off valve The ice maker requires a continuous water supply with a minimum pressure of 15 psig and a static pressure not to exceed 80 psig To ensure proper ventilation for your ice maker you need keep the front of the unit completely unobstru...

Page 8: ...Page 8 INSTALLATION CLEARANCE TOP VIEW of ICE MACHINE REAR VIEW of ICE MACHINE ...

Page 9: ...e production will be less than expected and operation will be noisy ELECTRICAL REQUIREMENTS Before you move your ice maker into its final location Be sure you have the proper electrical connection Refer to the nameplate rating at theleft of theicemachine tomake sure proper voltage properly grounded in accordance with National Electrical Code and local codes and ordinances is required The ice maker...

Page 10: ...cked on top of another machine a stacking kit will need to be installed Refer to the installation instructions included with the stackingkit WATER SUPPLY The water supply should be ready at the point of installation The water supply pressure should be a minimum of 15 psig with a static pressure not more than 80 psig A wall outlet directly behind the ice maker will make installation easier Tools re...

Page 11: ...ne 9 Is the ice cube machine plugged in 10 Have you turned on the main water supply and the tap 11 Have you checked for leaks at all water supply connections Control Panel in the front panel of the machine You will find the control panel in the front panel of the machine This control panel offers four pressure sensitive buttons and a LCD display screen 1 ON OFF Button Powers the ice machine 2 BinF...

Page 12: ... When ice cubes are taken out from the ice storage bin releasing the water curtain the machine will judge the status for three minutes During this period the LCD screen will display the words of Bin Full Release and 3 Min To End Bin Full Release flashes until the words 3 Min To End changes to 0 Min To End At this time the ice maker will start to make ice automatically 7 TO CLEAN THE MACHINE press ...

Page 13: ...al 20 has been set at the factory for optimum performance You can change it according to the quality of water ICE BRIDGE SIZE ADJUSTMENT GUIDE 1 Press and hold the ADJUST button for at least 3 seconds The unit will enter the Ice Size Adjustment mode and the words Ice Adjust display on the LCD Screen 2 While in the Ice Size Adjustment mode press the Clean button or the Mode button for the desired i...

Page 14: ...nedinthewatertank Asthewaterflows to the freezing evaporator surface the water freezes and sticks to the ice cube molds During the ice making process fresh water enters the water tank continuously as the water from the tank freezes continuously on theevaporator NORMAL SOUNDS Your new ice cube machine may make sounds that are unfamiliar to you Most of the new sounds are normal Hardsurfaceslikethefl...

Page 15: ...lly convenient to sanitize the tank after the ice making system has been cleaned and the ice storage bin is empty The ice storage bin should be sanitized occasionally Follow these steps to clean the tank and the bin 1 Disconnect power to the unit 2 Using a knifepoint or similar tool t o remove the plastic covers on the top and bottom front panel 3 Using a Phillips screwdriver remove the screws the...

Page 16: ... or how effective your filtration maybe Withhardwaterof15to20grains gallon 4to5grains liter youmayneedtoclean thesystem as often as every 3 months 1 Using tools to remove the plastic cover and screws fixed in front panel swing the front panel open 2 Make sure all ice is off evaporator If ice is being made initiate harvest or wait for cycle completion then turn machine off at the power switch 3 Rem...

Page 17: ...R SERVICE If the unit appears to be malfunctioning read through the OPERATION section of this manual first If the problem persists check the Troubleshooting Guide on the following page The problem may be something verysimplethatcanbesolvedwithoutaservicecall WARNING The ice machine cleaner contains acids DO NOT use or mix with any other solvent based cleaner products Use rubber gloves to protect h...

Page 18: ...ce from ice storage bin Normal condensation on the door or some water together with ice Take care when you take out ice Water supply connection leaks Tighten fitting See Connecting the water line Cubes are partially formed or white at the bottom Not enough water in the water trough Check if the water supply pressure is below 15 psig Check water supply filter may be restricted Check for a water lea...