26 / 43
Problem B :
The platform will not go up or down
Cause
: Lifting system limit switches not connected or defective.
Solution
: Completely collapse lift system and check switch
Batteries flat.
(red leds 2x flashing on battery condition indicator)
Charge up the batteries with the charger
Battery terminals make bad contact
Clean and re-tighten battery terminals
Key switch is OFF
Turn on the key switch to vertical position
Emergency stop button pressed in
Unlock emergency stop button (pull out)
Overload
Reduce load - maximum 120/250/450/550kg
Hydraulic fluid level too low
Top up hydraulic fluid (scissor raised - information from supplier)
Switch/push-button defective
Try using the scissor control service button (2) next to the main switch
80 amp fuse blown
Consult your dealer
Control current 10A fuse is blown
Consult your dealer
Stabilizers not extended (only with 3-scissor and 4-scissor model)
Turn the stabilizers out enough for extra support
Problem C : Speed difficult to regulate
Cause C
: Speed regulator switch is faulty
Solution
: Consult your dealer
Drive motor regulator is faulty
Consult your dealer
Problem D : BENOMIC has fallen over
Cause D
: - Wrongly lifted with forklift truck
- Unstable pipe rail system
- Too much manual pressure
- Overloaded
- Alignment indicator ignored
- Run into the path next to the pipes
- Lifting on the pipes or ground surface not level
Solution
:
1. Switch off the trolley
2. Lift the trolley back into position
3. Remove caps and covers
4. Disconnect batteries
5. Clean the trolley
6. Assess the damage
7. Identify cause and find solution (remove)
8. Carry out checks according to table in chapter 7
9. Carry out checks according to 7.1
!!!Beware of fluids - battery acid is extremely corrosive!!!