Battery empty
Battery charged
Floater must float
to read valid
value
Scale
Floater
Battery acid
Read
Read
7.1
PIPE RAIL SYSTEM MAINTENANCE
The pipe rail system used for the Berg Hortimotive
’s pipe rail trolley should be
inspected periodically. The system must conform to the directives for pipe rail
systems in the horticulture industry. Do not use a pipe rail system that fails to meet
the specified directives. Employers are also obliged to periodically check their
means of labour and ensure these conform to the means of labour regulations.
7.2
TECHNICAL MAINTENANCE
Repairs and maintenance on the parts mentioned below must be carried out by a
qualified professional recognised by the manufacturer:
All work relating to electrical components and wiring.
All work relating to the hydraulic system.
All work relating to the motor drive and reduction gear unit except for cleaning,
readjustment or replacement of the chain and chain wheels.
All maintenance should be noted in the maintenance logbook (appendix).
7.3
BATTERY MAINTENANCE
Charge the batteries at least twice a week with a suitable charger!! Prevent the
batteries from becoming depleted completely!
Please contact your dealer for a comprehensive product information pack on
batteries. Please find below directions for use and maintenance.
CAUTION!
-
Explosive gas is released during battery recharge. Avoid smoking, fire and
naked flames.
-
Only recharge the batteries in well-ventilated areas.
-
Check fluid levels on a weekly basis. The battery fluid must be at least 1cm
above the plates.
-
Only fill up with distilled water.
The b
attery’s lifespan is reduced considerably if
recharged unnecessarily. Immediate recharge of
empty batteries substantially increases the
lifespan. The lifespan of the batteries and charger
are adversely affected if the batteries are
discharged to under the 20% level Consequently,
the specific gravity of the acid should preferably be
checked on a weekly basis using an acidimeter.
The density of fully charged batteries is 1.28kg/l.
Percentage Density (in kg/l) = Voltage (Volts)
100%
1.28
12.7
80%
1.24
12.5
60%
1.21
12.3
40%
1.17
12.1
20%
1.14
11.9