background image

 

 

 

 

1. Important notes 

 

1.1. Applications 

 

The compressor is intended for compressing air only. Its use to compress other gases 
requires prior agreement with machine manufacturer or vendor. Such agreement must be 
made in writing. The compressor may not be used for any purpose other than specified. 

 

1.2. Operation 

 

While operating the compressor: 

-

 

Observe the instructions provided in the Manual and Warranty Book.

 

 

-

 

Technical and operating checks should be performed by the manufacturer or 
authorised service, using the manufacturer’s parts and consumables.

 

-

 

During the warranty period, use only manufacturer’s parts and consumables.

 

 

1.3. Other remarks and instructions 

 

-

 

The KOMPBERG BKB22 TWIN booster compressor will reach its maximum 
compression pressure only when 1.0-1.3 MPa is applied on the suction side from 
the screw compressor,

 

 

-

 

Operators should observe general H&S rules for boosters; also the technical 
supervision body regulations for pressure equipment shall apply,

 

 

-

 

An air tank selected individually by our technicians is necessary to ensure proper 
functioning of the KOMPBERG BKB22 TWIN boosters.

 

 

2. Operating safety rules 

 

The present rules are valid for BERG compressors. In addition to the H&S and Technical 
Supervision regulations applicable to compressors, their assemblies and accessories, the 
safety instructions given below should be followed in particular. The operators are 
supposed to observe safe work practices. It is the user’s responsibility to continuously 
maintain the compressor fully operable. Components and equipment considered to be no 
longer suitable for safe operation should be promptly replaced. Adjustments, installation, 
operation, maintenance and servicing should be entrusted only to properly trained, 
qualified and authorized staff. 

 

The limit values (pressure, temperature, time settings etc.) are given in the Technical 
Data section. 

 

 
 

The limit values may not be changed by the user. 

 

The manufacturer accepts no responsibility for any injury, damage of equipment or the 

compressor itself, at present and in the future, resulting from user’s negligence and failure 
to observe the installation, operation and maintenance requirements contained herein. No 
responsibility is also taken for failure to observe valid safety standards relating to the 
equipment and qualified staff. 

 
 

2.1. Basic requirements for safe transport and positioning of the boosters 

 

In addition to the general H&S and Technical Supervision regulations, the following rules 
must be observed: 

 

-

 

Use only H&S compliant and approved by the Technical Supervision lifting 
equipment to lift the compressor. Fix in place all rotating or loose parts of the 
machine before lifting it. It is strictly forbidden to stand in the hazardous range of 
the lift operation. Machine movement can be accelerated or slowed down only 
within applicable limits.

 

 

-

 

The compressor is transported on wooden pallets which should be secured against 
movement during transport. Fasten the compressor frame with cargo straps to 
appropriate holders on the vehicle platform to prevent it from sliding or overturning.

 

 

-

 

All screw and pipe connections should be of appropriate size and designed for a 
given operating pressure.

 

-

 

The compressor is not designed to operate outdoors.

 

 

 
 

Summary of Contents for KOMPBERG BKB22 TWIN

Page 1: ...Operating and Maintenance Manual KOMPBERG BKB22 TWIN BOOSTERS ...

Page 2: ...both the choice you have made and the cooperation you started with us Our compressors are machines of top quality which is the guarantee for a long years and reliable performance Our sales and service staff is available to answer all your queries regarding the installation and operation of your compressor You are also encouraged to use our warranty and post warranty technical service ...

Page 3: ...iption 7 4 1 Applications 7 4 2 Main components 7 4 3 The compressor 7 4 4 Electric motor 8 4 5 End cooler 8 4 6 Booster compressor frame 8 4 7 Control and protection equipment 9 5 Technical data 10 6 Operating description 10 6 1 Air circuit 10 6 2 Lubrication system 10 6 3 Oil pressure control 11 7 Unit operation and maintenance 12 8 Periodic maintenance and servicing 13 9 Procedure for important...

Page 4: ... Components and equipment considered to be no longer suitable for safe operation should be promptly replaced Adjustments installation operation maintenance and servicing should be entrusted only to properly trained qualified and authorized staff The limit values pressure temperature time settings etc are given in the Technical Data section The limit values may not be changed by the user The manufa...

Page 5: ...e done on the tank The plugs and other tank components can be removed only after tank depressurisation to the atmospheric pressure General safety rules should apply while depressurising the air tank The air must be vented slowly Keep the air stream away from people Do not allow oil spill around the compressor It is strictly prohibited to service the safety valves or to change their settings Do not...

Page 6: ...ators To ensure sufficient heat extraction the ventilators should have summarised capacity around 15 20 higher than the total cooling air requirement for all compressors in the room The air temperature in the room should range between 5 C to 40 C Provide sufficient room for maintenance operations 3 2 Power supply system requirement The booster compressor is designed to be supplied by a five conduc...

Page 7: ...t is a single stage compressor with two cylinders one side action with V cylinder arrangement at 90 angle The compressor has a tunelled iron cast crankcase The crankcase bottom serves also as an oil sump with the oil suction filter built in The oil filter is installed in the oil pump Two cylinders with valves are mounted to the crankcase The valves are held in place in their seats in the head with...

Page 8: ...r cooler collectors valves for draining condensate and a relief solenoid valve are provided Air circulation in both solutions is forced by a fan driven by an electric motor 4 6 Booster compressor frame The KOMPBERG BKB22 TWIN booster frame on which the motor and compressor are supported is made of plate and seated on four shock absorbers Booster KOMPBERG BKB22 TWIN 1 Compressor 8 Cooler 2 Electric...

Page 9: ...ide When the preset discharge pressure is reached the booster switches to idle run i e the relief valves open and the booster inlet valve closes A suction pressure sensor is also mounted on the suction manifold which protects the compressor booster against excessive pressure ratio together with a discharge pressure sensor which must be mounted on a high pressure air receiver A safety valve is plac...

Page 10: ...Hz 3Ph capacity measured acc to ISO 1217 1999 momentary value of acoustic pressure corrected by C characteristic does not exceed 130 dB equivalent acoustic pressure level corrected by A characteristic does not exceed 85 dB A 6 Operating description 6 1 Air circuit The air supplied to the head passes through the head chamber and suction valve to the cylinder Once compressed in the cylinder the air ...

Page 11: ...tion pipe The adjustment should be performed when the compressor has heated up and after the state of heat balance has been reached i e after 0 5 hour of work Secure the locknut and cap nut back when the adjustment is finished Oil pomp Manometer connection Adjust the oil pressure by unscrewing decreasing the pressure or tightening increasing the pressure Lock the screw with a locknut Screw on the ...

Page 12: ...it operation and maintenance Before each start and at least once a day check oil level in the crankcase and top it up if necessary check the connections open the breather valve for about 10 seconds the valve should be closed during normal operation vent valve opened closed ...

Page 13: ...00 working hours made by the authorized Berg Change V drive belts Kompressoren service Disconnect the unit from its power source and depressurise it to the atmospheric pressure before you proceed with any of the above service operations 9 Procedure for important service operations 9 1 Oil filter replacement Turn off the booster compressor close the valve on the discharge and suction lines Turn off...

Page 14: ...nd check for leaks 9 3 Check valve cartridge replacement 563 38 000 Turn off the booster compressor close the valve on the discharge and suction lines Turn off power supply and secure it against being reconnected by unauthorized persons After waiting for at least 5 minutes open the safety valve on the radiator by pulling the stem Undo the screws and remove the valve body from the side of the compr...

Page 15: ... by pulling the stem Drain the oil completely and screw the drain plug back in Pour new oil through the inlet to reach the max level mark Screw the threaded plug tightly by hand into the oil inlet Slowly open the valves on the suction and discharge lines Start the compressor and check for leaks and the oil level replenish if necessary Use only Synthetic compressor oil PNEUMOIL ST150 KOMPBERG BKB22...

Page 16: ...ty replace if contaminated necessary oil temperature insufficient quantity of oil replenish until maximum level is too high reached bearings fitted too close fit properly contaminated bearings rinse bearings leaking or damaged working repair and check valves for valves tightness protection for piston rings in remove deposits from rings and reduced grooves grooves compressor excessive wear replace ...

Page 17: ......