Check if all doors/covers are closed.
-
Open the valve that shuts off the compressor from compressed air system.
-
Check the “EMERGENCY STOP”
button position.
-
Switch on the compressor power supply.
When the compressor and compressed air system condition is checked, you can proceed with
starting the compressor.
To start the compressor, press the "START" button on the control panel. The compressor motor
starts working and depending on the overpressure in the compressed air system,the machine
switches to the loaded operation mode or, if the overpressure in the compressed air systemis
higher than the minimum start pressure, it switches to the stand-by mode and starts again after
its drop.
Incorrect rotation direction of the screw block rotors for more than 5 seconds will damage
the screw compressor.
Proper direction of screw air end rotation
6.2. Restart (after longer downtime)
Follow the procedure described below to start the compressor which has been out of use or
stored for over 3 months:
Check if there is no water in the screw assemble.
Turn the compressor shaft several times by hand in the rotating direction.
check oil level in the screw assembly body, top it up if necessary,
Perform the trial run of the compressor screw block lasting for at least 15 minutes.
During the trial run, check the machine for correct operation, noise, vibration, oil leaks and
tightness of connections in the compressed air system.
Rotating
direction of
CD8D