The cleaning
-
Clean the above pressure filter with clean water after every spray!
-
Clean the sprayer boom according to the recommendations in Appendix 4!
-
Clean the
METO
Spray Trolley using a soft brush, dampen cloth and/or compressed
air
-
Never clean the
METO
using a high pressure or steam cleaner (this can damage the
electrical circuit)
-
Clean the spray boom and hoses with pure water after spraying with chemicals
-
Remove still water to prevent the formation of Legionella bacteria
-
See also Appendix 5
9.9
Charging the batteries
Charge the batteries according to the status indication of the BATTERY STATUS
screen between the 50 and 10% remaining capacity and try to approach the 10% as
closely as possible according to the following advice.
On the BATTERY STATUS screen you can check the status of the batteries. At 100%, the
batteries are full, the lower the residual capacity the batteries are more discharged.
If during automatic driving the alarm message "low battery voltage, Charge battery! "
appears on the screen the batteries should directly be charged. Turn off the METO with
the Emergency Off switch and charge the battery continuously for minimal12 hours or until
the charger indicates full. (refer to the user manual of the charger!)
Recharge "during operation!" before the BATTERY STATUS screen indicates 50%
discharge should be avoided. Always try to match the approximately 10% discharge
status. This has the following advantages:
• Less charging cycle, is favorable for the life span
• Reduces water consumption
Charge the batteries every time after using and then at least once a month
regardless of use with a suitable charger!! Prevent deep discharge batteries, this
gives severe damage and a shorter lifetime!!
See also the instructions in Appendix 3 battery safety sheet!