Module data
Power supply (24 V power pack)
Supply voltage
+24 VDC (-15 % / +20 %) SELV,
max. alternating component: 5 %,
max. voltage interruption 1 ms (10 ms only with power supply after
61131-2)
Current consumption
Typically 1.0 A; max. 2.0 A at +24 VDC;
Fusing depending on the I/O load, max. 12 A
Polarity reversal protection
Yes
Potential isolation
Yes, between CAN bus and I/Os.
Ethernet port
Number / interface type
1 x 10/100 Base-T
Connection method
RJ45
USB ports
Number / interface types
1 x host USB, Rev. 1.1 (on rear)
2 x host USB, Rev. 1.1 (on front)
Plug/unplug cycles
Max. 1,000
CAN bus ports
Number / interface types
2 x Standard CAN ISO 11898
Potential isolation
CAN0 (X6) potential isolated
Transmission rate
Max. 1 Mbit/s
Terminating resistor
Switchable
Serial ports
Number / interface types
2 x RS232
1 x RS485
Potential isolation
RS485 (X8) potential isolated
Terminating resistor
Switchable with the RS485
E-bus port
Interface type
I/O expansion bus for up to 7 E-bus subscribers
Expansion slots
Number / interface types
3 slots for 3 I/O modules or 2 I/O modules and one AnyBus
®
module
Further features
Real-time clock
Yes, battery backed.
SD card
1 SD card slot or RS232 (X5)