7. Mount the cartridge in the headshell, and just tighten slightly, such it is possible to turn the cartridge.
Connect the cartridge clips to the cartridge pins. (Note the colour!). Pic. 9.
Note:
The cartridge clips must be handled with the greatest care!
8. Mount the counter weight.
Turn on the airsupply.
Adjust the tracking force. See the cartridge manual for recommended tracking force.
Note:
The tonearm must slide frictionless on the airpipe, when adjusting the tracking force.
9. Turn of the airsupply. (To ensure the platter do not turn).
Place the alignment tool on top of the platter, and make sure the groove is completely parallel to the
tonearm airpipe. It is recommended to use a calliper for exact measuring. Pic. 10.
Measure both end, Pic. 11 and 12.
10. Adjust the VTA:
Loosen the screw on the tonearm backside. Adjust the VTA, such as the armtube is parallel to the alignment
tool, Pic. 13. Tighten the screw.