Prepare the supply voltage
Respective connection cables should be provided for the power supply of the
device.
The Windows versions must be connected to a power supply 24 V DC (see
accessories).
The Android versions have a limited PoE capability. When selecting the supply
voltage, the intended use must be considered.
A 24 V DC auxiliary voltage is available when
-
the device is integrated into a door communication system (Elcom)
-
Audio-files are played-back (music, internet-radio)
-
no PoE-supply (Power over Ethernet) is available)
Ongoing exceeding of the permissible PoE-power consumption, from
increased use of the audio applications may lead to the PoE power supply
switching off.
Installing connector (RJ45) on the network cable (figure 11)
The flush-mounted housing is installed firmly in the wall. The empty conduit
with the network cable is guided through an entry on the housing.
Insert the network cable through the metal cap's earthing cover of the
connector.
Strip the Ethernet strands of the network cable, do not remove insulation.
Insert the strands into the plug-in connector (19) of the connector and bend
up 90°. Shorten any protruding strands.
When doing so, it is imperative to observe the colour code EIA/TIA -568 A
or B of the system. This can be found in the documentation of the installed
network components and routers. The Ethernet connection has been con-
nected to the device compatible with wired networks in accordance with
TIA/EIA-568-A or B
Insert the plug-in connector into the connector (20) and snap it shut.
The plug-in connector is locked in place in the connector.
Tighten the enclosed cable tie over the earthing cover.
z