Safety warnings
Attention: Electrical equipment must be installed
and fitted by qualified electricians.
Failure to observe any of the installation
instructions may result in irreparable damage, in
fire and in other hazards. To prevent electric
shocks, disconnect the mains supply (by cutting
out the circuit breaker) before working on the load
or on the device itself.
Function
The RolloTec
®
cut-off relay is installed between the
control element and the motors when two
conventional drive motors are to be controlled from
one control element. Among the control elements that
can be used are all RolloTec
®
controls, EIB controls
and blind/shutter switches or pushbuttons.
The instructions of the motor manufacturers
concerning the switch-over time at changes of the
running direction must be observed to avoid
damage to the motors.
If more than 2 motors are to be connected in parallel,
several cut-off relays can be used. In this case, all
blind/shutters are controlled centrally from one control
element (see fig.
A
).
Do not connect more than 6-8 motors at maximum to
one circuit breaker (observe the current rating). In all
other cases, distribute the load over more than one
circuit breaker.
If the blinds/shutters are to be controlled from more
than one control element, this can only be
accomplished with the extension units for the
RolloTec
®
inserts (see fig.
B
).
Important
•
It is not permitted to connect 2 control
elements to a single cut-off relay.
Simultaneous actuation of different running
directions would inevitably cause irreparable
damage to the motors or the control elements.
•
Use only blind or shutter motors equipped
with limit switches (mechanical or electronic).
Fitting
Rail-mounted cut-off relay REG
Install the cut-off relay REG only in distributions or
control cabinets on a 35 mm DIN rail.
Flush- or surface-mounted cut-off relays UP/AP
Install the cut-off relay UP/AP in a flush-mounting box
with blind-plate cover or behind a RolloTec
®
insert or
in a separate distribution box. The type of protection
achieved is dependent on the distribution box used.
Technical data
Rated voltage:
AC 230 V / 50 Hz
Control voltage:
AC 230 V / 50 Hz
Switching capacity:
8 A resistive load
3 A inductive load (in
accordance with VDE)
Current consumption: 10 mA
Connections:
0.5 bis 2.5 mm² single wire
0.5 bis 1.5 mm² stranded wire
with ferrules
Dimensions (mm) REG:
70.5 x 45 x 40
UP/AP:
52 x 50 x 22
Acceptance of guarantee
We accept the guarantee in accordance with the
corresponding legal provisions.
Please return the unit postage paid to our central
service department giving a brief description of
the fault:
Gebr. Berker GmbH & Co.
Abt. Service Center
Klagebach 38
D-58579 Schalksmuehle
Telefon: +49 (0) 2355 / 90 5-0
Telefax: +49 (0) 2355 / 90 5-111
RolloTec
®
RolloTec
®
cut-off relay REG
(rail-mounted device)
Order no. 2931
RolloTec
®
cut-off relay UP/AP
(flush-mounted / surface-
mounted device)
Order no. 2930
Operating instructions
More Information
Berker GmbH & Co. KG, Klagebach 38
58579 Schalksmühle/Germany
T49 (0) 23 55/9 05-0
T49 (0) 23 55/9 05-111
www.berker.de
825 547 01 08.2004
1
N
L
2
M
N
L
AC 230 V
Trenn-
relais
M2
M1
N
L
Bild B
cut-off
relay
M2
M1
N
L
cut-off
relay
M2
M1
N
L
UP/AP
cut-off
relay
M1
N
L
REG
M2
cut-off
relay
M2
M1
N
L
cut-off
relay
M2
M1
N
L
1
N
L
2
M
N
L
AC 230 V
Bild A
The -sign is a free trade sign addressed
exclusively to the authorities and does not
include any warranty of any properties.