Draft version 02 Operatots Manual / SmartMonitor SHIP L
page 24 of 26
MANUAL SYNC
MANUAL SYNC will be shown
on the 7-segment display, the
cloud symbol crossed out
circle is displayed
and USB
and Bluetooth sign is
blinking.
Configuration is needed.
Load configuration.
Press quickly 3 times the
multifunctional button
Or check if a configuration is
available for that device in
Berlinger SmartView software
(version 6.0 and higher).
if no communication to
SmartView Cloud is possible,
configuration needs to be
loaded manually
Manual SYNC
Manual SYNC will be shown
on the 7-segment display as a
ticker information and at the
cloud symbol crossed out
circle is displayed
.
Manual upload of data is
needed.
Manual upload with USB or
Bluetooth is needed.
Upload the data manually to
Berlinger SmartView software
(version 6.0 and higher).
Upload via Bluetooth will be
available in a later version.
LOW -.-°C
LOW -.-°C
will be shown on
the 7-segment display and the
exclamation mark is
blinking.
The measured temperature is
out of specified temperature
range of SmartMonitor SHIP L
device.
FLY:ON
Device will send no real time
data and on 7-segment
display shows
FLY:ON
Flight mode is activated. To
deactivate Flight mode press
5 times short the
multifunctional button
On the back of the device is a 3D-code which links to the Berlinger website where more information
about this device is available.
If more help is needed, contact Berlinger support at