background image

22

7. Spare Parts

6. Tools

Part Number

Designation

Comments

101217

Color plug set, right/left for  
CP/CPx BTE

1 red and 1 blue

145367

Colour plug set, right/left for  
Power BTE

1 red and 1 blue

142708

Colour plug set, right/left to lock 
TAR battery drawer for Power BTE

1 red and 1 blue

136395

Color plug set, right/left for  
Micro and Nano BTE

2 red and 2 blue

156570

Ear grips (10 pcs.)

For miniFit thin tubes

162758

Magnet for Auto-T

For CPx/CP/P/M BTE

Part Number

Designation

Comments

166243

Accessory Kit CPx/CP/P/M BTE

Contains:
· Cleaning cloth
· Auto-T magnet
· MultiTool

144367

Accessory Kit Nano BTE

Contains:
· Cleaning cloth
· MultiTool

101484

Battery door removal tool set

For Micro, CP, and CPx BTE

166313 

TAR Locking Set for Power BTE

Contains:
·  Color plug set, right/left  

to lock the TAR battery drawer 

·  Blue tool to unlock the TAR  

battery drawer

890-22-270-00

Disassembly Tool for lock pin

Summary of Contents for Compact Power BTE

Page 1: ...Compact Power Plus BTE Compact Power BTE Micro BTE Power BTE Nano BTE BEHIND THE EAR HEARING INSTRUMENTS Fitting Guide...

Page 2: ......

Page 3: ...oustic Options 6 Fitting Ranges 7 Attaching and Removing the Earhook or Thin Tube Adapter 8 Changing the Dome 9 Installation of Right Left Indicators 9 Replacing the Battery Door 11 DAI and FM Adapter...

Page 4: ...th thin tube system Micro BTE with Thin Tube System also available with earhook Bernafon Veras IFU micro BTE VR_ILU_microBTEwithHook_BW_HI 2a 1 4 3 2 5 6 1 1 Multi control 2 Microphone 2a Second micro...

Page 5: ...nafon nano BTE IFU VR_ILU_nanoBTEwithSpira_BW_HI 2a 8 1 7 6 5 4 2 3 1 Push button 2 Microphone 2a Second microphone 3 Adapter 4 Thin tube 5 Sound outlet 6 Dome 7 Concha clip 8 Battery door 1 NE_ILLU_P...

Page 6: ...the fitting software only one set of options either Spira Flex or miniFit is given However the table below will help you make the appropriate selection when you wish to use the other set of options S...

Page 7: ...ing Ranges 250 500 1 000 2 000 4 000 8 000 0 20 40 60 80 100 120 dB HL Frequency Hz 250 500 1 000 2 000 4 000 8 000 0 20 40 60 80 100 120 dB HL Frequency Hz 0 20 40 60 80 100 120 250 500 1 000 2 000 4...

Page 8: ...lace the hook or adapter with the desired part 3 Replace the lock pin tweezers make this easier Nano BTE 1 Pull the adapter or the hook upwards from the instrument 2 Replace with a new hook or an adap...

Page 9: ...break off the marker 3 Close the battery door Micro BTE Nano BTE 1 Pull the used dome off the thin tube and discard 2 With clean hands firmly push a new dome onto the thin tube as far as it will go If...

Page 10: ...nsert the marker end into the slot as shown 3 Twist and rotate the stick to break off the marker 4 Close the battery door Power BTE 1 Open the battery door 2 Insert the marker end into the slot as sho...

Page 11: ...ition and use the tweezers to place the pin into the hole 4 Use the flat end of the tweezers to push the pin completely in VR_ILU_NanoBTEbatteryDrawerRemove1_CMYK_HI VR_ILU_NanoBTEbatteryDrawerRemove2...

Page 12: ...nsert the screwdriver into the slit in the bottom of the instrument and push to open Micro BTE Compact Power Compact Power Plus BTE Power BTE 1 Open the tamper resistant battery door 2 Insert the spec...

Page 13: ...2 With the battery in place plug the DAI or FM adapter as shown 3 Close the battery door 4 To remove the DAI or FM adapter open the battery door and unplug Compact Power Plus Compact Power and Micro...

Page 14: ...r Direct Audio Input DAI enables the hearing aid to receive signals directly from external sources such as a TV personal stereo PC audio output MP3 player etc The DAI Adapter offers a Euro plug connec...

Page 15: ...act Power and Micro BTE Power BTE Bernafon Veras IFU micro BTE VR_ILU_DaiFMAdapterOnMicroBTE_BW_MOD_HI VR_ILU_MicroCompactBTEprogramAdapter_BW_HI 1 Open the battery door fully There is no need to inse...

Page 16: ...U_NanoBTEprogConnectCable_BW_HI VR_ILU_NanoBTEprogRemoveCover2_BW_HI Nano BTE 1 Remove the cover with the small tool as shown 2 Plug the cable into the connector 3 To replace the cover hook the top en...

Page 17: ...ut the product its functions and pairing it with the PC Please read the Instructions for Use carefully before using FittingLINK with Oasis Getting Started Please prepare FittingLINK and pair it with y...

Page 18: ...gLINK Instructions for Use Open Oasis and click Detect If FittingLINK is not selected as the default programming interface select the FittingLINK option from the pull down menu besides the Detect butt...

Page 19: ...ption Comments 589 25 070 00 Spira Flex Thin Tube 0 9 mm size 0 left Clamshell containing 5 Spira Flex thin tubes 0 9 mm 589 25 071 00 Spira Flex Thin Tube 0 9 mm size 1 left 589 25 072 00 Spira Flex...

Page 20: ...123311 Dome Large Vent 10 mm 123312 Dome Large Vent 12 mm 123307 Dome Small Vent 8 mm Single vented domes Bag including 10 domes 123308 Dome Small Vent 10 mm 123309 Dome Small Vent 12 mm 123293 Power...

Page 21: ...standard NOAHlink Blue left 384 20 034 00 Prog cable Nr 2 New standard NOAHlink Red right Part Number Designation Comments 144720 FittingLINK Wireless programming interface Part Number Designation Com...

Page 22: ...red and 2 blue 156570 Ear grips 10 pcs For miniFit thin tubes 162758 Magnet for Auto T For CPx CP P M BTE Part Number Designation Comments 166243 Accessory Kit CPx CP P M BTE Contains Cleaning cloth A...

Page 23: ...23...

Page 24: ...nit 15 Kitchener Ontario Canada N2R 1A7 Phone 1 519 748 6669 Toll Free 1 800 265 8250 Toll Free Fax 1 888 748 9158 Since 1946 we have been passionate about developing quality hearing systems that enab...

Reviews: