8.
Storing the generating set
Generating sets which are to remain unused for a long period of time must undergo certain procedures, in order to keep them in good
condition. Check that the storage area is not dusty or humid. Clean the exterior of the generating set and apply rustproofing product.
n
Close the fuel tap (
OFF
position), remove the sediment bowl and drain it.
o
Open the fuel tap (
ON
position) and drain the petrol from the tank into a suitable container.
p
Refit the sediment bowl and tighten fully.
q
Drain the carburettor by loosening the drain screw. Collect the petrol in a suitable container.
r
Change the engine oil.
s
Remove the spark plug and pour about 15 ml of oil into the cylinder, then refit the spark plug.
t
Leave the engine to run for a few moments to distribute the oil in the cylinder.
u
Clean the generating set and cover the engine again to protect it from dust.
v
Store the generating set in a clean, dry place.
9.
Troubleshooting
Probable causes
Remedial action
The generating set is being charged during start-up
Take it off charge
Fuel level too low
Fill up with fuel
The fuel tap is closed
Open the fuel tap
Fuel supply blocked or leaking
Have the system repaired
Blocked air filter
Clean the air filter
Control on "
О
"
Place the control on "
I"
The engine will not
start
Defective spark plug
Replace the spark plug
Probable causes
Remedial action
Blocked ventilation inlets
Clean the air inlet and outlet guards
The engine cuts out
Probable overcharge
Check the charge
Probable causes
Remedial action
Circuit-breaker tripped
Reset the circuit breaker
Circuit-breaker faulty
Have it checked, repaired or replaced
Faulty socket
Have it checked, repaired or replaced
Faulty appliance supply lead
Change the lead
No electric current
Faulty alternator
Have it checked, repaired or replaced
Probable causes
Remedial action
Circuit breaker trips
out
Faulty equipment or lead
Have it checked, repaired or replaced