ENGLISH
5.6.2 Automatic timer “OFF”
Briefly press black “learn” button consecutively twice.
5.7 Light at “CLOSE”
If the lighting is to stay on even with the door closed,
(operator lighting stays switched on for approx.150 sec.
when door is closed) this can be achieved by the following
action:
1) First unplug from the mains.
2) Press the black "learn" button and keep it pressed.
3) Plug back into the mains.
4) After the lamp has switched on, release the "learn"
button.
On repeating the procedure, at the "CLOSE" position
the light switches off again to 5 sec. lightning time.
6 Use of the garage door operator
Only ever operate the garage door operator provided
you have a full view of the door's area of movement.
Wait until the door has come to a complete halt before
entering the door's area of movement.
Before driving in or out of the garage, always check that
the door has fully opened!
Note
Initial function checks as well as programming or extending the
remote control should always take place from inside the garage.
ATTENTION
Keep hand transmitters out of the
reach of children!
The function of the mechanical release should be
checked every month. The pull cord with knob may
only be actuated when the door is closed, otherwise
with weak, broken or defective springs or due to
inadequate counterbalancing, there is a risk that the door
could close too quickly.
ATTENTION
Never hang bodily from the pull cord
with knob!
All persons using the door system must
be shown how to operate the garage
door operator properly and safely.
Demonstrate
and test the mechanical release as
well as the safety return.
To do this,
halt the movement of the closing
door by grasping it with both hands.
The door system should gently cut-
out and initiate the safety return. The
same should happen during the
opening cycle, i.e. the door system gently cuts out and the
door comes to a halt.
6.1
Normal operation
In the normal operation mode the garage door operator
works entirely according to impulse repetition control,
whereby it makes no difference whether an external
button, a programmed-in hand transmitter button or
the test button on the control PCB is pressed:
1st impulse: The door travels towards an end-of-travel
position.
2nd impulse: the door stops.
3rd impulse: the door travels in the opposite direction.
4th impulse: the door stops.
5th impulse: the door travels in the direction of the end-
of-travel position selected with the 1st
impulse
etc.
The operator lighting comes on when the door starts to
move and automatically goes out 5 or 150 sec. later on
completion of the cycle.
6.2
Operation following actuation of the mechanical/
manual
release
If, for instance due to a mains power failure, the
mechanical release was actuated, the carriage must
reengage in the door link latch before normal operation
can be resumed:
1) Press the green button on the carriage (see figure
17
).
2) Move the door manually until the carriage reengages
in the door link latch.
3) Allow the door to complete several uninterrupted
opening and closing cycles to check whether it has
fully closed and fully opened.
The operator is now ready again to resume normal
operation.
Note
If, after carrying out several interrupted door cycles,
the behaviour of the door does not correspond to that
described in stage 3, it will be necessary to rerun the
learning procedure (see section 3.2.2).
6.3 Error messages operator lighting / LED-diagnosis
(Lighting diodes, see figure
7.1
)
Via the LED-diagnosis 3 and 4, which are visible after
opening the transparent lid, causes for malfunctions can
be easily identified. During the normal operation these
LEDs are not lighting.
Lighting: flashes once within 1 second
LED:
4
glows
Cause:
A emergency-stop function connected to
terminals 12 and 13 has been interrupted or
activated
(see
section
4.8).
Remedy:
The STOP or emergency-OFF circuit is to be
closed.
Note:
If a STOP or emergency-OFF circuit is not
connected to terminals 12 and 13, check
whether the DIP switch 1 (SCH1) is set at
"ON".
Lighting: flashes once within 1 second
LED:
4
flashes
Cause:
A photocell connected to terminals 20 and 71
has been interrupted or activated (see
section
4.9/4.10).
Remedy:
Remove the obstruction causing the problem
and/or check the photocell, if necessary
replace.
44
Summary of Contents for GA 401
Page 2: ...Deutsch 3 Fran ais 9 English 6 Nederlands 12 2...
Page 16: ...7 01 2006 GA201 401 V2 0 AL 15 2 3 1 3a 1 4a 16...
Page 21: ...12 01 2006 GA201 401 V2 0 AL E E 3 1a E E 3a 3 1a 21...
Page 22: ...13 01 2006 GA201 401 V2 0 AL E E E E DF 98 N 80 3 1b 3 1b 3b 22...
Page 23: ...14 01 2006 GA201 401 V2 0 AL 2 12 5 4 1 4 2 2 11 1 4 2 2 11 1 4 1 2 11 2 6 4 1 2 11 1 6 1 F 23...
Page 24: ...15 01 2006 GA201 401 V2 0 AL 4 4 4 5 6 2 7 7 2 9 15 LD3 LD4 7 1 7 2 24...
Page 28: ...19 01 2006 GA201 401 V2 0 AL 3 x 3 2 1 18 1 sec 3 x 2 x 2 x 6 sec 3 2 2 19 3 2 4 20 28...
Page 68: ...04 2006 V1 0_D DA20 RE 32 2900874 Verkoop BeNeLux www bsr agenturen nl 2900874...