background image

For Safe Use Of Your Patio Heater:

• DO NOT leave the heater unattended. Keep children and pets

away from the appliance at all times.

• Never use the Patio Heater LP regulator and hose with any other

appliance. Only use the Bernzomatic supplied pressure regulator
and hose assembly in Bernzomatic patio heater.

• Always operate the unit on a level surface.

• This appliance is to be used only outdoors in a well ventilated

space and should 

NEVER

be used in a building, carport, garage,

porch, covered patio, tent, any other enclosed area, under an
awning on a boat or a surface that can catch fire.

• Use Patio Heater at least 3 ft. from any wall or surface and 3 feet

from any overhead structure. Maintain 10 ft. clearance to objects
that can catch fire or sources of ignition such as pilot lights on
water heaters, live electrical appliances, etc.

NEVER

place near

plants, under trees or under an awning.

• Clothing or other flammable materials should 

NEVER

be hung

from the heater, or placed on or near the heater.

• The area around the heater must be kept clear and free from

combustible materials, gasoline and other flammable vapors and
liquids.

WARNING:

Certain materials or items, when stored under the

heater, will be subject to radiant heat and could be seriously
damaged. DO NOT store any flammable materials or containers
other than the gas tank in the tank compartment.

• This appliance is hazardous as it has high temperatures on

various surfaces and children and adults should take adequate
care so as to avoid burns or clothing ignition.

• Guards removed for servicing or cleaning should 

ALWAYS

be

replaced prior to operating the Patio Heater.

NEVER

operate

without the guards in place.

• This appliance is not intended for and should never be used for

cooking food.

• Vents and openings must not be blocked. Clean and remove

debris to ensure adequate air is available for combustion and
ventilation.

ALWAYS operate the heater with 20 lb. tank in the correct
position as shown.

ALWAYS

remove the 20 lb. tank from the Patio Heater when

transporting.

NEVER CHECK FOR GAS LEAKS WITH A MATCH OR OPEN
FLAME.

• Prior to operation check the gas supply hose for signs of

damage. The damaged hose MUST be replaced prior to the
appliance being put into operation. If there is evidence of
excessive abrasion or wear or if the hose is damaged in any
other way replace the hose and regulator with an approved
BERNZOMATIC replacement.

• When replacing the tank into the compartment, ensure that the

gas supply hose is neatly routed so that there are no jams or
kinks and that it is clear of any sharp or abrasive edge or moving
edge or surface.

• All repairs should

ALWAYS

be done by a qualified service person.

More frequent cleaning may be necessary and it is imperative
that control compartment, burners and circulating air
passageways of the heater are kept clean and free from debris.

• This appliance is designed for use only with a 20-pound LP-gas

supply tank (propane) constructed and marked in accordance
with the specifications for LP-gas tanks of the U.S. Department of
Transportation (DOT). The tank must be provided with a shutoff
valve terminating in an LP-gas supply tank valve outlet specified,
as applicable, for connection No. 510 in the Standard for
Compressed Gas Tank Valve Outlet and Inlet Connections,
ANSI/CGA-V-1. The tank supply system must be arranged for
vapor withdrawal and must include a collar to protect the tank
valve.

• The gas tank must be stored outdoors in a well-ventilated area,

out of reach of children. Disconnected tanks must have threaded
valve plugs tightly installed, and must not be stored in a building,
garage or other enclosed area.

• When the heater is not in use, close tank valve and disconnect

from heater.

Safety Tips

• The use of alcohol, prescription or nonprescription drugs may

impair the consumer’s ability to properly assemble or safely
operate the appliance.

• Never move the Heater while in operation or still hot. Allow the

appliance to cool before moving or storing.

• The regulator may make a humming or whistling noise during

operation. This will not affect safety or use of the Patio Heater.

• If you have a Patio Heater problem see the Troubleshooting

Section.

• Light the burner and check to make sure that the flame is in a

continuous ring. Curing of paint and parts will produce an odor
only on first lighting.

SAFE USE OF YOUR GAS PATIO HEATER

WARNING

SAFE USE OF YOUR GAS PATIO HEATER

1-800-654-9011

5

1-800-654-9011

6

WARNING

• When the Patio Heater is not in use and unattended, always turn

the pilot flame to the 

OFF

position by depressing the control

knob, turning clockwise to 

a full stop

. Also turn the 20 lb. LP

tank to 

OFF

by turning hand-wheel clockwise to 

a full stop

.

Young children should be carefully supervised when they
are in the area of the heater.

MAINTENANCE INSTRUCTIONS

• Prior to operation check the gas supply hose for signs of

damage. The damaged hose must be replaced prior to the
appliance being put into operation if there is evidence of
excessive abrasion or wear or if the hose is damaged in any
other way. Replace the hose with only an approved 
Bernzomatic replacement.

• At the start of a season check the burner on full flame, viewing

through the pilot window, for yellow tipping, floating or lift off.
Refer to the diagram below. If any of these conditions occur
then please call for a qualified serviceman.

• The surfaces of the heater can be cleaned using a mild detergent

and a soft cloth.

IGNITER CHECK
With the tank regulator/valve in the “Off” position

, push “Igniter

Button” until audible clicks are heard. At this point a small blue
spark should be seen through the pilot window between the
electrode and the pilot shroud. This operation can be repeated
several times if you miss seeing the spark.

Always use approved Bernzomatic replacement parts when your
heater needs repair and use a qualified gas serviceman to carry
out any repairs.

Replacement parts are available from your local Bernzomatic
dealer as listed at the end of this manual.

INSTALLATION AND SAFETY PRECAUTIONS

• This Patio Heater is designed for use with LP (propane) gas. The

regulator and hose supplied must be used. Replacement parts
must be those specified by the manufacturer.

• The Patio Heater installation must conform with local codes, or in

their absence with National Fuel Gas Code, NFPA 54/ ANSI
Z223.1 or CAN/CGA-B149.2 Propane Installation Code. Handling
and storage of LP tanks must conform to LP Gas Code
NFPA/ANSI 58. The Patio Heater is not to be used in houses,
buildings, garages, carports, covered patios, tents, under
awnings, in recreational vehicles or on boats. Keep any electrical
cords and/or fuel supply hoses well away from hot surfaces.

• This Patio Heater is certified for use in the United States and

Canada only. Do not modify for use in any other location.
Modification will result in a safety hazard.

This product is subject to patents pending in the US and other
countries.

CORRECT

YELLOW

BLUE LIFTING

Summary of Contents for PH3250B

Page 1: ...y cuidado antes de intentar utilizar el producto El cliente debe conservar estas instrucciones para referencia futura This patio heater is designed for outdoor use only Read and follow all safety sta...

Page 2: ...tion adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipm...

Page 3: ...tentiellement dangereuse qui si elle n est pas vit e peut entra ner des blessures mineures ou mod r es Certaines pi ces peuvent comporter des ar tes vives portez au besoin des gants de protection Le d...

Page 4: ...include a collar to protect the tank valve The gas tank must be stored outdoors in a well ventilated area out of reach of children Disconnected tanks must have threaded valve plugs tightly installed...

Page 5: ...s shown below Connecting the Adapter Hose to the LP Tank 1 Use only adapter hose approved by safety testing organizations CSA UL etc 2 Turn all control knobs to the OFF position 3 Turn LP tank OFF by...

Page 6: ...rr s et ne doivent pas tre rang s dans un b timent un garage ou un autre endroit ferm Lorsque vous n utilisez pas l appareil fermez le robinet du r servoir et d branchez le de l appareil Conseils de s...

Page 7: ...qu il est illustr ci dessous Assemblage du raccord interm diaire et du r servoir de GPL 1 N utilisez qu un raccord interm diaire approuv par les organisations de v rification de la s curit CSA UL etc...

Page 8: ...cluir un collar n para proteger la v lvula del tanque El tanque de gas debe ser almacenado en el exterior en un rea bien ventilada y fuera del alcance de los ni os Los tanques desconectados deben tene...

Page 9: ...reas sombreadas que se muestran abajo A S lo use tanques equipados con este tipo de v lvula El tanque debe estar en posici n vertical mientras est en uso Rueda manual del dispositivo de protecci n de...

Page 10: ...est facile d acc s El control de gas con encendido electr nico est colocado en el centro para facilitar el acceso Integrated wheels allow for easy transport Les roues int gr es facilitent le d placeme...

Page 11: ...une solution savonneuse s il y a des fuites de gaz Conecte el regulador al tanque de gas y verifique que no haya escapes de gas usando una soluci n jabonosa Fit the tank into the chamber taking care n...

Page 12: ...5 minutes et r p tez l tape 12 Si el piloto no se enciende gire la perilla a la derecha a la posici n Off apagado Espere 5 minutos y repita el paso 12 1 800 654 9011 21 1 800 654 9011 22 Place match o...

Page 13: ...tanque Remove safety screws Remove knob from control panel and store in door Enlevez les vis de s ret Retirez le bouton du panneau de commande et remettez le dans la porte l endroit pr vu cet effet R...

Page 14: ...a veilleuse Appuyez sur le bouton de commande sans le tourner et tenez le enfonc pendant 30 secondes Rel chez le et attendez 5 minutes avant d allumer nouveau Le gaz ne circule pas V rifiez si le r se...

Page 15: ...______________________________________________________ Serial Number in tank compartment _______________________________________________________________________ Date Purchased ________________________...

Page 16: ...or death and may void the warranty Distributed by Bernzomatic MEDINA NY 14102 USA Model No PH3200S Serial No XXXXXX Normal Input Rating 40 000 BTU Hour Normal Input Pressure 11 WC Minimum Input Pressu...

Reviews: