Installation Instructions……………………………………..………………………..pag.2
Inserting the hotplate……………………………………………..…………………..pag.3
Requirements……………………………………..……………………………….…..pag.3
Attaching the hotplate……………………………………..………………………….pag.4
Gas connection……………………………………..…………………………………pag.4
Electrical connection……………………………………..……………………….…..pag.5
Wiring diagrams……………………………………..…………………………….…..pag.5
Room ventilation…………………………………….…………………………………pag.5
Location and venting…………………………………….…………………………….pag.5
Replacement of nozzles……………………………………..………………………..pag.5
Regulation of burners……………………………………………...………………….pag.6
Descriptions…………………………………………………………………………….pag.6
Service & maintenance instructions……………………………..…………………..pag.6
Greasing the valves……………………………………………..…………………….pag.7
User instructions……………………………………………..………………………..pag.7
Using burners……………………………………………………..……………………pag.7
Cleaning the appliance……………………………………………..…………………pag.8
Figures………………………………………………...…………..……………………pag.19
Installation instructions
This appliance shall only be installed by an authorized person. This appliance shall be installed in
accordance with the manufacturers installation instructions, IMPORTANT: this appliance must be
installed in accordance with the norms in force of the country concerned.
The installation of this appliance must conform to local codes and ordinances. In the absence of
local codes, Installations must conforms to American National Standards,
National Fuel Gas Code
ANSI Z223.1 – latest edition** or B149.1.
If local codes permit, a flexible metal appliance connection with the new AGA or CGA certified
design, max. 5 feet (1,5 m) long, ½” I.D. recommended for connecting this cooktop to the gas supply
line. Do not bend or damage the flexible connector when moving the cooktop. The pressure regulator
has ½” female pipe thread. You will need to determine the fitting required, depending on the size of
your gas supply line, the flexible metal connector and the shutoff valve.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in
the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping
system any pressure testing of that system at test pressure in excess of ½ psi (3,5 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal
to or less than ½ psi (3.5 kPa).
For use with a pressure regulator. The regulator supplied must be used with this appliance.
The gas appliance pressure regulator must be set for the gas with which the appliance is used.
This appliance can be used with Natural Gas and LP Gas. It is shipped from the factory adjusted for
use with Natural Gas: CONVERSION FIXED ORIFICES ARE LOCATEDIN THE LITERATURE PACK
SUPPLIED WITH THE UNIT.
Injectors kit for the change of type of gas are contained inside the package jointly with the hob
installation kit and Instruction booklet.
The maximum inlet gas supply pressure incoming to the gas appliance pressure regulator is 20’’
water column (5 kPa) .