background image

 

2

WARNING 

Read this instruction booklet before installing and using the appliance. 

The manufacturer will not be responsible for any damage to property or to persons caused by incorrect  

installation or improper use of the appliance. 

The manufacturer reserves the right to make changes to its products when considered necessary and useful, without 
affecting the essential safety and operating characteristics. 

This appliance has been designed for non-professional, domestic use only. 

 

Warning: do not use this appliance to heat a room. 

Installation instructions

  

This appliance shall only be installed by an authorized person. This appliance shall be installed in accordance 
with the manufacturer’s installation instructions, IMPORTANT: this appliance must be installed in accordance 
with  the norms & standards of the country where it will be installed. 

The installation of this appliance must conform to local codes and ordinances. In the absence of local codes, 
Installations must conforms to American National Standards, National Fuel Gas Code ANSI Z223.1 – latest 
edition** or B149.1. 

If local codes permit, a flexible metal appliance connection with the new AGA or CGA certified design, max. 5 
feet (1,5 m) long, ½” I.D. is recommended for connecting this appliance to the gas supply line. Do not bend or 
damage the flexible connector when moving the appliance. The pressure regulator has ½” female pipe thread.  
The appropriate fitting must be determined based on the size of your gas supply line, the flexible metal 
connector and the shutoff valve. 

The appliance, when installed, must be electrically grounded  in accordance with local codes or, in the absence 
of local codes, with the National Electrical Code, ANSI/NFPA 70. 

The appliance and its individual shutoff  valve must be disconnected from the gas supply piping system any 
pressure testing of that system at test pressure in excess of ½ psi (3,5 kPa). 

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve 
during any pressure  testing of the gas supply piping  system  at test pressures equal to or less than ½ psi (3.5 
kPa). 

For use with a pressure regulator. The regulator supplied must be used with this appliance; it shall be properly 
installed in order to be accessible when appliance is installed in its final location. 

The gas appliance pressure regulator must be set for the gas with which the appliance is used. 

This appliance can be used with Natural Gas and LP Gas. It is shipped from the factory adjusted for use with 
Natural Gas: CONVERSION FIXED ORIFICES ARE LOCATED IN THE LITERATURE PACK SUPPLIED WITH THE 
UNIT. 

A gas nozzle

 kit for the change of type of gas are contained inside the package tigether with the gas 

appliance installation kit and instruction booklet.  

The maximum inlet gas supply pressure incoming to the gas appliance pressure regulator is  20’’ water column 
(5 kPa) . 

The minimum gas supply pressure for checking the regulator setting shall be at least 1“ w.c. (249 Pa) above the 
inlet specified manifold pressure to the appliance (this operating pressure is 4” w.c.     (1.00 kPa) for Natural Gas 
and 11” w.c. (2.75 kPa) for LP Gas. 

ATTENTION: A manual valve shall be installed in an accessible location in the gas line external to the appliance 
for the purpose of turning on or shutting off gas to the appliance 

WARNING: Do not use aerosol sprays in the vicinity of this appliance while it is in operation 

Requirements 

 

Room ventilation – Location and venting. 

ATTENTION:

 An exhaust fan may be used with the appliance; in each case it shall be installed in conformity with 

the national standards in force. 
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be installed in 
conformity with the national standards in force. 

Summary of Contents for CB36500X

Page 1: ...al codes Electrical installation must be in accordance with the current CSA C22 1 Canadian Electrical Codes Part 1 and or local codes Installation of any gas fired equipment should be made by a licensed plumber A manual gas shut off valve must be installed in the gas supply line ahead of the oven in the gas flow for safety and ease of service In Massachusetts All gas products must be installed by ...

Page 2: ...he gas supply piping system any pressure testing of that system at test pressure in excess of psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psi 3 5 kPa For use with a pressure regulator The regulator supplied must be used ...

Page 3: ...In order to increase the clearance between front edge of the worktop and the burners for your safety it is recomended to install the worktop frontguard supplied with the appliance For installation instructions follow the instructions indicated in the following figures ...

Page 4: ...earance to combustible vertical surfaces above 36 91 4 cm I the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 6 15 2 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop 4 4 Wall cabinets above the rangetop must be a minimum of 36 91 4 cm for the open top burner models and a minimum of 42 106 7 cm for the sealed burner models above the rangetop co...

Page 5: ...t be grounded and properly polarized The unit is equipped witth a SJT power cord and in case of replacement the cable shall be replaced with one of the same type size and length WARNING Electrical Grounding Instructions This appliance is equipped with a three prong plug for your protection against shock hazard and should be plugged directly into a properly grounded socket Do not cut or remove the ...

Page 6: ...ing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing For freestanding gas range model CB36500X C3W0 U7X 2 or 5 A CAUTION label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing ...

Page 7: ...uring any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kPa 3 Flexible Connections a If the unit is to be installed with flexible couplings and or quick disconnect fittings the installer must use a heavy duty AGA design certified commerciai flexible connector of at least 1 2 1 3 cm ID NPT with suitable strain reliefs in compliance with ANSI ...

Page 8: ... regulator for use with the other gas different from which one it is pre arranged it is enough perform the following operations 1 Unscrew by hand the upper metal stopper of the regulator 2 Unscrew by hand the white plastic piece screwed under the above mentioned metal stopper afterward screw it again in opposite way under the metal stopper for gas reference see the written LP and NAT with relative...

Page 9: ...73 LP Propane 11 6300 1845 1500 439 0 36 Rapid Front L 1 55 NG 4 10400 2046 2500 732 Regulated 0 98 LP Propane 11 11400 3339 2500 732 0 47 Centre Inner 0 80 NG 4 2730 799 900 264 Regulated Dual Burner 0 50 LP Propane 11 2900 849 900 264 0 29 Centre Outer N 2 x 1 30 NG 4 15000 4394 4500 1319 Regulated N 2 x 0 83 LP Propane 11 16400 4804 4500 1319 0 65 CAUTION save the orifices removed from the appl...

Page 10: ...SCRIPTIVE CAPTION FOR HOB DESCRIPTION OF HOBS 1 Small Burner Model CB36500X CB36M500X C3W0 U or A 7X 2 or 5 A Fig A 2 Medium burner Model CB36600X CB36M600X C3Y0 U or A 7X 2 or 5 A Fig B 3 Rapid burner 4 Dual burner Fig A Fig B CONTROL PANEL DESCRIPTION On the control panel small symbols show the function of each knob or key Here as follows are the several controls that a cooker can have the symbo...

Page 11: ...e other one Tips for using burners correctly WARNING During use of each gas burner s adjust the burner flame size properly so it does not extend beyond the edge of the cooking utensil This is an instruction based on safety considerations Use suitable pots for each burner see Fig and Table When the liquid is boiling turn down the knob to the MINIMUM position Always use pots with a cover Correct fla...

Page 12: ...be cleaned frequently with soapy water Never use abrasive powder Do not leave acidi or alkaline substances on the enamelled parts such as vinegar lemon juice salt tomato sauce etc and do not wash the enamelled parts while they are still hot Cleaning the stainless steel parts Clean the parts with soapy water and dry them with a soft cloth The shine is maintained by periodically using specific stain...

Page 13: ...uct used in any commercial application 2 Repair service provided by other than a Bertazzoni authorized service agency 3 Damage or repair service to correct service provided by an unauthorized agency or the use of unauthorized parts 4 Installation not in accordance with local electrical codes or plumbing codes 5 Defects or damage due to improper storage of the product 6 Defects or damage or missing...

Page 14: ...save service Refer to warranty certificate for warranty condiftions Dealer Importer Name address phone MANUFACTURER BERTAZZONI SPA VIA PALAZZINA 8 42016 GUASTALLA REGGIO E ITALY Tel 0522 226411 telefax 0522 226440 http www bertazzoni com SERVICE CENTERS Name Phone ...

Reviews: