9
EN
•
The power supply cable must be positioned
in such a way that it is not resting against the
rear of the oven, that it is not in contact with
sharp edges and will not reach a temperature
of 90°C at any point.
•
Do not use adapters, extension leads, gang
sockets etc. as these could cause loose
contacts and overheat.
When the appliance is to be hard-wired to the
mains circuit:
•
The circuit must be fi tted with a omnipolar
circuit breaker of suitable capacity for the
appliance's rated load.
•
The earth conductor must not be switched
by the breaker and must be connected to the
earthing system.
•
As an alternative, an RCBO may also be used,
or RCD protection in addition to or instead of
a fuse or MCB, depending on the applicable
electrical code.
REPLACING COMPONENTS
Isolate the appliance’s power supply before
performing any maintenance.
Contact an authorised service centre if functional
components require replacement.
WARNING: If the power cable requires
replacement,
the
installer/maintenance
technician must use H05VV-F cable and leave
the earth conductor around 2 cm longer than
the live and neutral wires. They must also
comply with the instructions given for the
initial electrical connection.
/ Installation
MAINTENANCE
MAINTENANCE