E
5
B. Horizontal Ventilation System
STEP 1
• Remove the screws (1) and (2) for opening the blower motor
cover and save screws. Remove cover. See Figure 6.
Blower motor cover
Back of OVEN
Figure 6
STEP 2
• Remove the screws (3) for Blower attachment and save
screws. See Figure 7.
Before : Fan blade openings facing Front
Figure 7
• Lift blower unit out of mounting location. See Figure 8.
Blower motor
Figure 8
CAUTION:
Do not pull or stretch blower wiring.
STEP 3
• Turn the blower unit so that the fan blade openings are
facing back (rear of unit). See Figure 9.
CAUTION:
Wires to blower unit must be routed properly to
avoid pinching wires before reinstallation of cover plate.
After : Fan blade openings facing Rear
Figure 9
• Use side cutters or tin snips to cut and remove parts B from
back plate. Be careful not to distort the plate. See Figure
10.
Parts B
Figure 10