BEFORE

 

INSTALLATION

 

This

 

appliance

 

shall

 

only

 

be

 

installed

 

by

 

an

 

authorized

 

professional.

  

This

 

appliance

 

shall

 

be

 

installed

 

in

 

accordance

 

with

 

the

 

manufacturer’s

 

installation

 

instructions.

 

This

 

appliance

 

must

 

be

 

installed

 

in

 

accordance

 

with

 

the

 

norms

 

&

 

standards

 

of

 

the

 

country

 

where

 

it

 

will

 

be

 

installed.

 

The

 

installation

 

of

 

this

 

appliance

 

must

 

conform

 

to

 

local

 

codes

 

and

 

ordinances.

 

In

 

the

 

absence

 

of

 

local

 

codes,

 

Installations

 

must

 

conforms

 

to

 

American

 

National

 

Standards,

 

National

 

Fuel

 

Gas

 

Code

 

ANSI

 

Z223.1

 

 

latest

 

edition**

 

or

 

B149.1.

 

The

 

appliance,

 

when

 

installed,

 

must

 

be

 

electrically

 

grounded

 

in

 

accordance

 

with

 

local

 

codes

 

or,

 

in

 

the

 

absence

 

of

 

local

 

codes,

 

with

 

the

 

National

 

Electrical

 

Code,

 

ANSI/NFPA

 

70.

 

If

 

local

 

codes

 

permit,

 

a

 

flexible

 

metal

 

appliance

 

connection

 

with

 

the

 

new

 

AGA

 

or

 

CGA

 

certified

 

design,

 

max.

 

5

 

feet

 

(1,5

 

m)

 

long,

 

½”

 

I.D.

 

is

 

recommended

 

for

 

connecting

 

this

 

appliance

 

to

 

the

 

gas

 

supply

 

line.

 

Do

 

not

 

bend

 

or

 

damage

 

the

 

flexible

 

connector

 

when

 

moving

 

the

 

appliance.

  

This

 

appliance

 

must

 

be

 

used

 

with

 

the

 

pressure

 

regulator

 

provided.

 

The

 

regulator

 

shall

 

be

 

properly

 

installed

 

in

 

order

 

to

 

be

 

accessible

 

when

 

the

 

appliance

 

is

 

installed

 

in

 

its

 

final

 

location.

 

The

 

pressure

 

regulator

 

must

 

be

 

set

 

for

 

the

 

type

 

of

 

gas

 

to

 

be

 

used.

 

The

 

pressure

 

regulator

 

has

 

½”

 

female

 

pipe

 

thread.

 

The

 

appropriate

 

fitting

 

must

 

be

 

determined

 

based

 

on

 

the

 

size

 

of

 

your

 

gas

 

supply

 

line,

 

the

 

flexible

 

metal

 

connector

 

and

 

the

 

shutoff

 

valve.

 

The

 

appliance

 

must

 

be

 

isolated

 

from

 

the

 

gas

 

supply

 

piping

 

system

 

by

 

closing

 

its

 

individual

 

manual

 

shutoff

 

valve

 

during

 

any

 

pressure

  

testing

 

of

 

the

 

gas

 

supply

 

piping

  

system

  

at

 

test

 

pressures

 

equal

 

to

 

or

 

less

 

than

 

½

 

psi

 

(3.5

 

kPa).

 

All

 

opening

 

and

 

holes

 

in

 

the

 

wall

 

and

 

floor,

 

back

 

and

 

under

 

the

 

appliance

 

shall

 

be

 

sealed

 

before

 

installation

 

of

 

the

 

appliance.

 

A

 

manual

 

valve

 

shall

 

be

 

installed

 

in

 

an

 

accessible

 

location

 

in

 

the

 

gas

 

line

 

external

 

to

 

the

 

appliance

 

for

 

the

 

purpose

 

of

 

turning

 

on

 

or

 

shutting

 

off

 

gas

 

to

 

the

 

appliance

 

 

WARNING!

 

Do

 

not

 

use

 

aerosol

 

sprays

 

in

 

the

 

vicinity

 

of

 

this

 

appliance

 

while

 

it

 

is

 

in

 

operation

 

ROOM

 

VENTILATION:

 

An

 

exhaust

 

fan

 

may

 

be

 

used

 

with

 

the

 

appliance;

 

in

 

each

 

case

 

it

 

shall

 

be

 

installed

 

in

 

conformity

 

with

 

the

 

appropriate

 

national

 

and

 

local

 

standards.

 

Exhaust

 

hood

 

operation

 

may

 

affect

 

other

 

vented

 

appliances;

 

in

 

each

 

case

 

it

 

shall

 

be

 

installed

 

in

 

conformity

 

with

 

the

 

appropriate

 

national

 

and

 

local

 

standards.

 

 

TYPE

 

OF

 

GAS

 

This

 

appliance

 

is

 

shipped

 

from

 

the

 

factory

 

for

 

use

 

with

 

propane

 

lp

 

gas.

 

For

 

use

 

with

 

natural

 

gas

 

please

 

follow

 

the

 

conversion

 

procedure

 

described

 

on

 

pg.

 

15.

 

A

 

step

 

by

 

step

 

conversion

 

procedure

 

is

 

also

 

included

 

with

 

each

 

set

 

of

 

lp

 

gas

 

nozzles.

  

 

GAS

 

PRESSURE

 

The

 

maximum

 

inlet

 

gas

 

supply

 

pressure

 

incoming

 

to

 

the

 

gas

 

appliance

 

pressure

 

regulator

 

is

 

20’’

 

water

 

column

 

(5

 

kPa)

 

.

 

The

 

minimum

 

gas

 

supply

 

pressure

 

for

 

checking

 

the

 

regulator

 

setting

 

shall

 

be

 

at

 

least

 

1“

 

w.c.

 

(249

 

Pa)

 

above

 

the

 

inlet

 

specified

 

manifold

 

pressure

 

to

 

the

 

appliance

 

(this

 

operating

 

pressure

 

is

 

4”

 

w.c.

     

(1.00

 

kPa)

 

for

 

Natural

 

Gas

 

and

 

11”

 

w.c.

 

(2.75

 

kPa

  

for

 

LP

 

Gas).

 

 
 
 

Summary of Contents for PRO30 4 GAS AR

Page 1: ...AS RANGES Models PRO30 4 GAS X M7S0GNU7X 2 5 A Models PRO30 4 GAS AR M7S0GNU7S 2 5 A Models PRO30 4 GAS BI M7S0GNU7W 2 5 A Models PRO30 4 GAS NE M7S0GNU7N 2 5 A Models PRO30 4 GAS RO M7S0GNU7R 2 5 A Models PRO30 4 GAS VI M7S0GNU7L 2 5 A cod 310815 ...

Page 2: ...ppliances are designed according to the strictest safety and performance standard for the European and the North American market We follow the most advanced manufacturing philosophy Each appliance leaves the factory after thorough quality inspection and testing Our distributors and our service partners are ready to answer any questions you may have regarding how to install use and care for your Be...

Page 3: ...SSURE REGULATOR 14 GAS CONVERSION 15 STEP 1 PRESSURE REGULATOR 15 STEP 2 SURFACE BURNERS 16 STEP 3 MAIN OVEN BURNER 16 STEP 4 BROILER BURNER 17 STEP 5 VISUAL CHECKS 18 STEP 6 MINIMUM FLAME ADJUSTMENT 19 INSTALLATION CHECKLLST 21 FINAL PREPARATION 21 USER MANUAL ROOM VENTILATION 22 SURFACE BURNER LAYOUT 22 SURFACE COOKING 23 SYMBOLS 23 SURFACE BURNER OPERATION 23 TIPS FOR USING BURNERS CORRECTLY 24...

Page 4: ...ish hotline 866 905 0010 French 800 561 7625 Fax 714 428 0040 Email BERTAZZONIHELP SERVICEPOWER COM Mailing address SERVICEPOWER 1503 South Coast drive Suite 320 Costa Mesa CA 92626 REPLACEMENT PARTS Only Bertazzoni replacement parts may be used in performing service on the appliance Replacement parts are available from factory authorized parts distributors AP Wagner PHONE 716 961 7131 FAX 716 856...

Page 5: ...sary and useful without affecting the essential safety and operating characteristics This appliance has been designed for non professional domestic use only Do not use this appliance to heat a room Do not place any pot or pan on the open oven door The door is made of glass and it can break if loaded with a weight Before beginning installation please read these instructions completely and carefully...

Page 6: ...eight Burner power Natural gas LP gas Auxiliary 3730 BTU h 3750 BTU h Semi rapid 6000 BTU h 6300 BTU h Rapid 10400 BTU h 11400 BTU h Dual burner inner 2730 BTU h 2900 BTU h Dual burner outer 15000 BTU h 16400 BTU h Oven 14500 BTU h 14500 BTU h broiler 12000 BTU h 12000 BTU h ...

Page 7: ...r and the shutoff valve The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psi 3 5 kPa All opening and holes in the wall and floor back and under the appliance shall be sealed before installation of the appliance A manual valve shall be in...

Page 8: ... the unit Adjust leg height to the desired level by twisting the inside portion of the leg assembly until the proper height is reached Check with a level that the cooktop is perfectly level INSTALLING THE WORKTOP FRONTGUARD To increase the clearance between the front edge of the worktop and the burners it is possible to install the worktop frontguard shipped with the appliance To install the front...

Page 9: ...on the front part on the worktop Align the screw holes with the corresponding holes at the back of the worktop If the holes are not aligned partially loosen the brackets att the back of the worktop as shown below Install the front part of the backguard by tightening the 2 central screws from the top and 2 lateral screws from the bottom Position the back part of the backguard and secure it to the w...

Page 10: ...racket is 25 1 4 64 cm Secure the brackets to the wall with appropriate hardware Slide the range against the wall until the brackets are fully inserted into their receptacles on the back of the range INSTALLATION REQUIREMENTS ELECTRICAL A properly grounded horizontally mounted electrical receptacle should be installed no higher than 3 7 6 cm above the floor no less than 2 5 cm and no more than 8 2...

Page 11: ...e range shall be 13 33 0 cm EXHAUST HOOD INSTALLATION This range will best perform when used with PRO line Bertazzoni exhaust hoods These hoods have been designed to work in conjunction with the Bertazzoni range and have the same finish for a perfect look For maximum performance the height of the bottom of the hood from the worktop should be between 25 1 2 65 cm and 31 1 2 80 cm This would typical...

Page 12: ...is equipped with a three prong plug for your protection against shock hazard and should be plugged directly into a properly grounded socket Do not cut or remove the grounding prong from this plug WARNING ELECTRICAL SHOCK HAZARD Disconnect electrical power at the circuit breaker box or fuse box before installing the appliance Provide appropriate ground for the appliance Use copper conductors only F...

Page 13: ...iance shall be conducted according to the manufacturer s instructions Before placing the oven into operation always check for leaks with soapy water solution or other acceptable method MANUAL SHUT OFF VALVE THIS VALVE IS NOT SHIPPED WITH THE APPLIANC AND MUST BE SUPPLIED BY THE INSTALLER The manual shut off valve must be installed in the gas service line between the gas hook up on the wall and the...

Page 14: ...al gas 4 0 W c P LP Propane 11 0 W C P Incoming line pressure upstream from the regulator must be 1 W c P higher than the manifold pressure in order to check the regulator The regulator used on this range can withstand a maximum input pressure of 1 2 PSI 14 0 W c P If the line pressure exceeds that amount a step down regulator is required The appliance its individual shut off valve and the pressur...

Page 15: ... diameter printed on the body Consult the table on page 20 for matching nozzles to burners Save the nozzles removed from the range for future use STEP 1 PRESSURE REGULATOR The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with LP gas at a nominal outlet pressure of 11 w c or Natural Gas at a nominal outlet pressure of 4 w c and it is pre arranged f...

Page 16: ...thorized parts warehouse Each nozzle has a number indicating its flow diameter printed on the body Consult the table on page 20 for matching nozzles to burners STEP 3 MAIN OVEN BURNER To replace the nozzles of the main oven burner start by removing the bottom panel of the oven Loosen the screw located on the right side of the burner and pull out the burner from its support ATTENTION pay extra atte...

Page 17: ...air adjustment on the oven burner STEP 4 BROILER BURNER Loosen the screw and pull out the burner from its support ATTENTION pay extra attention to avoid damage to the igniter and thermocouple Using a 7 mm name of the tool unscrew the nozzle Replace the nozzle using the conversion set supplied with the range or by a Bertazzoni authorized parts warehouse Each nozzle has a number indicating its flow ...

Page 18: ...t gently the two connections alternating action on the two nuts Do not fully tighten one thermocouple before having started to tighten the second one B OVEN IGNITER AND THERMOCOUPLE POSITION The appropriate gap between the tip of the spark plug or thermocouple and the burner shall be approximately 1 8 The tip of the spark plug or thermocouple must fully overlap at least the first gas emission hole...

Page 19: ...ired minimum 4 Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position OVEN BURNER 1 Set the oven temperature control knob to the MAXIMUM setting 2 Close the oven door and operate the oven for at least 10 minutes 3 Set the knob to the MINIMUM setting corresponding to 270 F 132 C 4 Remove the knob 5 With a slotted screwdriver turn the choking screw b...

Page 20: ...apid Front R 1 17 NG 4 6000 1759 1500 439 Regulated 0 73 LP Propane 11 6300 1845 1500 439 0 36 Rapid Rear R 1 55 NG 4 10400 3046 2500 732 Regulated 0 98 LP Propane 11 11400 3339 2500 732 0 47 Front L Inner 0 80 NG 4 2730 799 900 264 Regulated Dual Burner 0 50 LP Propane 11 2900 849 900 264 0 29 Front L Outer N 2 x 1 30 NG 4 15000 4394 4500 1318 Regulated N 2 x 0 83 LP Propane 11 16400 4804 4500 13...

Page 21: ...h no yellow tipping sooting or flame lifting 13 Has the minimum setting for all burners been adjusted 14 Is the oven and broiler ignition working properly 15 Does the oven light work properly FINAL PREPARATION Before using the oven remove any protective wrap from the stainless steel All stainless steel body parts should be wiped with hot soapy water and with a liquid stainless steel cleanser If bu...

Page 22: ...n compartment for storage ROOM VENTILATION The use of a gas cooking appliance generates heat and humidity in the room where it is installed Proper ventilation in the room is needed Make sure the kitchen is equipped with a range hood of appropriate power 400 CFM minimum Activate the exhaust fan range hood when possible Intensive and continuous use of the appliance may require additional ventilation...

Page 23: ...ignition simply turn the control knob counter clockwise to maximum power position Press the knob to start the flow of gas and the ignition spark The spark will released at the metal tip of the white ceramic pin located on the side of the burner Once the flame is on release the control knob gently If the flame turns off repeat the above procedure The dual power burner is composed by two burners ins...

Page 24: ...When cooking with flammable fat such as oil do not leave the range unattended Use pots of the appropriate size on each burner following the indication of the diagram below When boiling liquids turn the knob to the MINIMUM position once boiling is reached to avoid overflow Always use pots with matching lid Dry the bottom of pans before operation Use pots with a flat thick bottom except for wok cook...

Page 25: ...knobs OVEN SHELVES Bertazzoni ranges are equipped with commercial grade shelves and a enamel cooking tray Shelves are mounted on the appropriate guides situated on the sides of the oven compartment Insert the shelf between top and bottom guide in any of the 5 positions available To keep the oven as clean as possible cook meat on the tray When available always follow recipe book directions Personal...

Page 26: ...ice for more than 15 seconds If after that period the burner has not been lit open the oven door and wait 60 seconds before trying to light the oven again With the oven door partially open turn the control knob to the maximum temperature setting position Press the control knob to start the gas flow and the ignition spark Wait 10 seconds after the burner has been completely lit before releasing the...

Page 27: ...ing the oven temperature To activate the broiler turn the control knob clockwise in the broiler position The broiler burner always operates at maximum power and therefore there is no temperature setting The operating symbols are silk printed on the knobs ELECTRIC IGNITION With the oven door completely open turn the oven control knob to the broiler position Press the knob to start the gas flow and ...

Page 28: ...ber spatula If food residue prevent the smooth operation of the control knobs call the customer servce hotline to schedule service by a factory trained professional Cleaning stainless steel for best results use a stainless steel cleaner product with a soft sponge or wipe Alternatively use a soft sponge or cloth with a warm soap and water solution Never use abrasive powders or liquids Cleaning the ...

Page 29: ...ng the below instructions After you open the door completely and lock the hinges fig 1 put the door in a semi open position and using both hands pull it towards you until it is released from the attachment To reassemble the door operate in reverse order They are also easily off the side grids by unscrewing the nuts that fasten the oven ATTENTION while cleaning the door avoid spillage of food resid...

Page 30: ..._________________________________________________________ _______________________________________________________________ INSTALLER _______________________________________________________________ ________________________________________________________________ SERVICER _______________________________________________________________ ________________________________________________________________ ...

Page 31: ...31 BERTAZZONI SpA Via Palazzina 8 42016 Guastalla RE ITALY WWW BERTAZZONI COM ...

Reviews: