22
82.475 / Boxer II
TRANSFERRING
9
- To transfer the liquid contained into the tank to another one, proceed as follows:
- To transfer the liquid contained into the tank to another one, proceed as follows (6).
- Turn all the valve handles to position
9
.
- Trip the switch which enables the spraying pump to be engaged.
- Engine speed should kept high enough to permit the filling operation (approximately 2,500 rpm).
FILLING
1
- Close the drain orifice using the valve (1) (figure 24, page 43).
- Fill the centrifugal pump priming tank with water. To do this, draw the hexagon socket head screw (1) located
on the upper part of the pump body (figure 3).
- Filling without incorporation hopper using:
- Connect the filling pipe (T1) on the quick-fitting union (3).
- Turn all the valve handles to position
1
.
- Put the pipe (T1) into the liquid to be suck.
- Trip the switch which enables the spraying pump to be engaged.
- Engine speed should kept high enough to permit the filling operation (approximately 2,500 rpm).
When the filling operation is finished, turn valve handle (3) to horizontal position, disconnect the filling
pipe (T1), replace the plug on the quick-fitting union.
- Filling with incorporation hopper using: (see page 30).
RINSING THE MAIN TANK WITH MAINS WATER
5
- Pump stopped:
- Connect the mains water hose (T3) to the quick connector (5).
- Turn all the valve handles to position
5
.
- Open the water supply.
- Drain the tank via valve (1) (figure 24, page 43).
RINSING THE MAIN TANK WITH THE RINSE TANK
6
- Pump stopped:
- Turn all the valve handles to position
6
. NOTE: For valve No. (1) place the handle in the "dashed" position
6
during 2 minutes, then turn the handle to the normal position
6
.
- Power up the control box, (reference, figure 19 - page 37).
- Stop spraying: switches (2) placed to the left of the control box (5) and press push-button (4) (figure 19 -
page 37).
- Trip the switch which enables the spraying pump to be engaged.
- Engine speed should be held at 1,400 rpm for proper rinsing.
- Drain the tank via valve (1) (figure 24, page 43).
RINSING THE SPRAYING CIRCUIT WITH THE RINSE TANK
7
- Pump stopped:
- Turn all the valve handles to position
7
.
- Power up the control box, (reference 1, figure 19 - page 37).
- Open spraying: switches (2) placed to the right of the control box (5) and press push-button (3) (figure 19 -
page 37).
- Trip the switch which enables the spraying pump to be engaged.
- Engine speed should be held at 1,400 rpm to obtain proper rinsing pressure.
This operation is not enough when changing chemical products.
CENTRIFUGAL PUMP FUNCTIONS
(figure 4)
- BOXER II 2500 / 3000 R -
Summary of Contents for BOXER II-1800
Page 2: ...2 82 475 Boxer II...
Page 14: ...14 82 475 Boxer II...
Page 26: ...26 82 475 Boxer II...
Page 27: ...27 82 475 Boxer II OTHER SPRAYER FUNCTIONS...
Page 29: ...29 82 475 Boxer II 1 2 3 4 5 6 a b T2 T3 a b a b 1 2 3 10 9 7 8 9 1 4 5 6 8 7 9 10 11 2 3 8 T1...
Page 35: ...35 82 475 Boxer II 1 2 3 4 5 6 a b T2 T3 16 17 I 0 a b 1 3 4 2 5 P T1...
Page 41: ...41 82 475 Boxer II ON OPTION Electric gauge 1 2 3 1 2 3 23 22...
Page 43: ...43 82 475 Boxer II 24 1...
Page 44: ...44 82 475 Boxer II...
Page 51: ...51 82 475 Boxer II 1 1 2 29 2 1 BOXER II 1800 R BOXER II 2500 3000 4000 R 2 30 31...