background image

BST-DL08 

Single-Use USB PDF Temperature 

Data logger 

Manual 

V1.0 

BESANTEK Corporation, CANADA 

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 

Summary of Contents for BST-DL08

Page 1: ...BST DL08 Single Use USB PDF Temperature Datalogger Manual V1 0 BESANTEK Corporation CANADA Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Page 2: ...oduction 1 2Application 1 1 3Product Feature 1 4Performance Parameters 1 Chapter II Instruction Manua 2 2 1Instrument appearance specification 2 2 2 Instrument instructions 3 2 3PDF document description 5 Chapter Ill Precautions 8 BESANTEK Corporation CANADA ...

Page 3: ...an be fixed screws installation more convenient and safe 1 2Application The product can be applied to cold storage vaccines and blood products food cold chain transportation containers transportation outdoor and other special environment 1 3Product Feature IP67 waterproof and dustproof design resistant to moisture condensation and dust Low power design 1 2AA 3 6V lithium battery can work continuou...

Page 4: ...nt into the recording mode When the instrument is turned on press short press this button the LCD will switch the display real time data minimum value MIN maximum value MAX alarm lower limit LO alarm upper limit HI cycle switching Instrument boot record state long press this button for 3 seconds the instrument off 3 upper limit lamp the temperature exceeds the upper limit state the light is on eve...

Page 5: ... of the recorded temperature at this time 6 Recording mark meaning the instrument is recording data now 7 Real time temperature 8 Temperature units 0 c and l can be switched display 2 21nstrument instructions Use Step set the instrument and synchronize the time instrument turn on and boot into calibration mode the instrument turn on again and recording data normally connect to the computer open th...

Page 6: ...rm the measuring temperature of the instrument is not in the range of the upper and lower limits of this setting will be alarming 5 Display unit select C option temperature display unit 0 c select F option temperature display unit r 6 Set record interval every record interval the instrument records a piece of data in seconds the set range is 5 43200S 7 Check the Update option the instrument synchr...

Page 7: ...r opening this disk a PDF file will appear Click this file to read the data recorded by this instrument and can copy and paste the PDF document to other computer disk Note 1 It is suggested to rename the PDF document according to actual needs after copying the PDF document Note 2 the recording capacity of this instrument is 12000 sets of data After the data storage reaches the upper limit the LCD ...

Page 8: ...26 7 Alarm2 Sy use Atarmsectr i 20 0 T 8 Alam IEvet1ts 0 9 a 30 0 T 10 AlannEvet1l S o 11 T 9g ed c 13 Originator Notes 12 l1iK 14 rCJ no 15 Trend graph 29 1 t 2 1 t _ _____ 1 210 _____ 1 1 t t 1 t t 1 t _ _ t _ t c 1 0 11 0 59 ___ 11 AO t l 43 20Hrtvt6 2011111116 20171UN6 Date Time _ Tflt IP Figure 2 6 PDF Document Page 1 1 Instrument serial number and software version 2 Over limit alarm prompt b...

Page 9: ... 201711Utli09 20 52 2ll 5 1011 11tlMOl 21 12 __ _ 2017 ttM10 30 52 2115 5 mrn1110 a1 201Tl11M10 32 s2 2115A 201 11nttet D Sl JU 2017 1111110 MS ll l 2011111M1o JIIS2 _ 20Wtt11tto Jl Q _ 201711tM10 37 52 215 5 20ffl111 1110 a IJ 20171111 1610 ll9 S2 2115 5 201 111 111CtilQSllll l 2011 111 111Cbll 52ll l 2011111Mt 2011t1tlll 1Q Qli2 JU 2017 111161Cbl4 52 2115 6 2011 111111Q ill IJ 20171111 1610 alS ...

Page 10: ...g function and shutdown 3 Button operation will increase the power consumption of the instrument and avoid a large number of useless operations on the keys when necessary 4 It can not be used for the second time if the instrument power off when recording the data so please do not turn off or connect the machine to the computer during the recording process VER 1 0 8 BESANTEK Corporation CANADA Test...

Reviews: