Installation Instructions for 34HW–35HW IDH Max Mortise Locks
BEST ACCESS SYSTEMS
Indianapolis, Indiana
11
Installation Instructions for 34HW–35HW IDH Max Mortise Locks
Installing the lock
12
Install trim hole inserts and bushings
1 Insert the two trim hole inserts into the upper trim
hole on each side of the door, as shown in Figure 12.
2 Insert two bushings into the field harness & reader
wire hole on each side of the door, as shown in
Figure 12.
3 Insert a bushing into the sensor & solenoid wire hole
on the inside of the door, as shown in Figure 12.
Note:
You do
not
need to change the positions of the
DIP switches on the control electronics circuit board
located in the inside escutcheon.
■
By default, switches 1 through 5 are set to ON. These
switches are for possible future applications.
■
By default, switches 6 and 7 are set to ON for
automatic baud rate detection. This setting lets you
determine the baud rate for communication between
the lock’s control electronics circuit board and the
panel interface module by setting DIP switches on the
panel interface circuit board. (See page 21.)
■
Switch 8 is set to OFF for locks with a swipe-type
magnetic stripe card reader, a proximity reader, or a
keypad reader; it is set to ON only for locks with an
insertion-type magnetic stripe card reader.
Figure 12 Installing the trim hole inserts and bushings
Outside of door
Trim hole
insert
Bushing
Trim hole
insert
Bushings
Inside of door
Summary of Contents for 34HW
Page 1: ......
Page 6: ...Contents vi W Series Service Manual...
Page 38: ...IDH Max Locks Functions and Parts 2 24 W Series Service Manual...
Page 54: ...Electrified Locks Functions and Parts 3 16 W Series Service Manual...
Page 140: ...Service and Maintenance for Cylindrical Locks 5 30 W Series Service Manual...
Page 158: ...Additional Service and Maintenance for IDH Max Locks 6 18 W Series Service Manual...
Page 162: ...Glossary A 4 W Series Service Manual...
Page 164: ...Installation Instructions B 2 W Series Service Manual...