Service and Maintenance for Cylindrical Locks
5–4
W Series Service Manual
Task B2. To remove the plain lever/knob:
Insert the protrusion on the spanner wrench into the hole on the
shaft of the lever, as shown in
. Slide the lever off the
sleeve.
Task C. To remove the access door:
1. Use the appropriate bit driver to remove the security screw from the
access door.
2. Open the access door and remove it from the inside escutcheon.
Task D. To disconnect the connections and remove the outside
escutcheon:
1. Remove the upper escutcheon and lower escutcheon screws from
the inside escutcheon. Pull the inside escutcheon away from the
door enough to expose the control electronics circuit board.
Note:
You can let the inside escutcheon dangle from the field wire
harness while completing Task D through Task H.
2. Disconnect the three sensor connections and solenoid connection.
Figure 5.3
Removing the plain lever
Protrusion on the spanner wrench
Lever shaft
Figure 5.4
Removing the access door
Security screw
Tabs