Service and Maintenance for Cylindrical Locks
5–12
W Series Service Manual
3. Tighten the RQE rose liner on the door with the through-bolts.
Task E. To reinstall trim hole inserts, bushings, and hub washers:
1. Insert the two trim hole inserts into the upper trim hole on each
side of the door.
2.
For LH and LHRB doors
Insert two bushings into the door status switch & LH/LHRB reader
wire hole on each side of the door.
For RH and RHRB doors
Insert two bushings into the field harness & RH/RHRB reader wire
hole on each side of the door.
3. Insert a bushing into the remaining wire hole on the inside of the
door.
Figure 5.13
Reinstalling the through-bolts and RQE rose liner (IDH Max shown)
RQE rose liner
Through-bolt
RQE wire
Solenoid wire
Inside of door
RQE rose liner
Hub washer
Summary of Contents for 34HW