6. Loosen the screw holding the harness clamp and remove the clip.
Save the clip.
7. Disconnect the reader wire harness from the reader circuit board.
Reinstalling the reader wire harness
1. Connect the reader wire harness to the reader circuit board.
2. Slide the harness clamp under the loosened screw. Tighten the
screw. See
3.
For magnetic stripe swipe and proximity card readers
, peel away
the protective backing from the edge of the escutcheon gasket and
slide the gasket onto the upper escutcheon post. Press the gasket
into place on the edge of the escutcheon so the reader circuit board
is covered.
4. Connect the reader wire harness to the control electronics circuit
board. For mortise instructions, see
. For cylindrical instructions, see
Tighten the RQE rose liner on the door with the through-bolts.
5. Reinstall the outside escutcheon. For mortise instructions, see
Task F. To secure the escutcheons and complete the connections:
. For cylindrical instructions, see
escutcheons and complete the connections:
6. Reinstall the inside lever/knob. For mortise instructions,
see
Task G. To reinstall the inside and outside levers/knobs:
. For cylindrical instructions, see
inside and outside levers/knobs:
Figure 6.2
Removing the harness clamp
Harness clamp
Reader wire harness
Lower left mounting screw
Control electronics circuit board
Summary of Contents for 34HW
Page 1: ......
Page 6: ...Contents vi W Series Service Manual...
Page 38: ...IDH Max Locks Functions and Parts 2 24 W Series Service Manual...
Page 54: ...Electrified Locks Functions and Parts 3 16 W Series Service Manual...
Page 140: ...Service and Maintenance for Cylindrical Locks 5 30 W Series Service Manual...
Page 158: ...Additional Service and Maintenance for IDH Max Locks 6 18 W Series Service Manual...
Page 162: ...Glossary A 4 W Series Service Manual...
Page 164: ...Installation Instructions B 2 W Series Service Manual...