Service and Maintenance for Mortise Locks
W Series Service Manual
4–7
2. Disconnect the three sensor connections and solenoid connection.
3. Disconnect the reader wire harness from the control electronics
circuit board.
Figure 4.6
Disconnecting the wire harnesses
Reader wire harness
connector
Sensor wires and
solenoid wires
Solenoid and sensor
wire harness
Inside of door
Inside escutcheon
Control electronics
circuit board