Service and Maintenance for Mortise Locks
4–8
W Series Service Manual
4. Remove the outside escutcheon from the door.
Caution
When removing the outside escutcheon, make sure that the reader
wire harness is not rubbed across any sharp edges or over any
surface that could damage its sleeving or wire insulation.
Figure 4.7
Removing the outside escutcheon from the door
Reader wire harness
connector
Field harness &
reader wire hole
Outside
escutcheon
Outside of door