Service and Maintenance for Mortise Locks
4–12
W Series Service Manual
Task H. To remove the inside escutcheon:
1. Remove the wire transfer hinge from the door and door frame.
2. Pull the wires and splice connectors out of the holes or pockets in
the door and frame.
3. Disconnect the leads.
4. Remove the inside escutcheon from the door and pull the field wire
harness out of the door.
Caution
When removing the inside escutcheon, make sure that the field wire
harness is not rubbed across any sharp edges or over any surface
that could damage its sleeving or wire insulation.
Figure 4.12
Disconnecting the field wire harness
Access holes
Field wire
harness leads
Wire transfer
hinge
Door frame
Field wires
Splice
connectors
Door