Service and Maintenance for Mortise Locks
4–18
W Series Service Manual
3. Insert a bushing into the sensor & solenoid wire hole on the inside
of the door.
4. From the outside of the door, feed the reader wire harness
connector through the field harness & reader wire hole.
5. Temporarily rest the outside escutcheon on the door by inserting
the trim studs into the stud holes.
Note:
You can temporarily install the outside lever/knob to hold the
outside escutcheon in place. See Task G on
6. Connect the reader wire harness to the control electronics circuit
board in the inside escutcheon.
7. Feed the solenoid and sensor wire harness from the control
electronics circuit board, as well as the solenoid and sensor wires
from the mortise case, through the large opening in the inside trim.
Caution
When routing the reader wire harness, make sure the reader wire
harness is not rubbed across any sharp edges or over any surface
that could damage its sleeving or wire insulation.
Figure 4.19
Feeding the reader wire harness connector through the door
Field harness &
reader wire hole
Outside escutcheon
Outside of door
Reader wire harness
connector
Summary of Contents for 34HW
Page 1: ......
Page 6: ...Contents vi W Series Service Manual...
Page 38: ...IDH Max Locks Functions and Parts 2 24 W Series Service Manual...
Page 54: ...Electrified Locks Functions and Parts 3 16 W Series Service Manual...
Page 140: ...Service and Maintenance for Cylindrical Locks 5 30 W Series Service Manual...
Page 158: ...Additional Service and Maintenance for IDH Max Locks 6 18 W Series Service Manual...
Page 162: ...Glossary A 4 W Series Service Manual...
Page 164: ...Installation Instructions B 2 W Series Service Manual...