8B. LI 720U-B71 and LI 1420U-B73 (120-volt) Specifications
8C. LI 720E-B72 and LI 1420E-B74 (230-volt) Specifications
8D. Runtime and Recharge Time Table
The table below shows runtimes and recharge times for the UPS and up to 3 external cab-
inets. Please note: the configurations shown in the table below provide the best com-
bination of runtime and recharge time. For other configurations, runtimes and
recharge times will be different.
E
N
G
L
I
S
H
Nominal Voltage:
120 VAC.
Compliance:
UL listed, cUL, FCC Class B.
Input Voltage Range:
91-144 VAC, user-adjustable to 84-150 VAC.
Output Voltage Range: 104-127 VAC, user-adjustable to 96-132 VAC.
Input Inlet:
IEC 320 C14 (LI720U-B71) or IEC 320 C20, 16-amp
(LI1420U-B73).
Output Receptacles:
LI 720U-B71: Six NEMA 5-15R.
LI 1420U-B73: Four NEMA 5-15R, one IEC 320-C19 (16-amp).
Ventilation:
Air around UPS must be free of dust, chemicals, or other mate-
rials that corrode or contaminate. Air must be free to move
around the UPS.
Battery:
Sealed, maintenance-free, valve-regulated operation. UL 924
recognized.
Operating
Environment:
0° to 40° C (32° to 104° F). 0 to 95% relative humidity (without
condensation). 0-10,000 feet.
Nominal Voltage:
230 VAC.
Compliance:
TÜV certified, CE certified.
Input Voltage Range:
175-277 VAC, user-adjustable to 161-287 VAC.
Output Voltage Range: 200-244 VAC, user-adjustable to 184-253 VAC.
Input Inlet:
IEC 320 C14 (LI720E-B72) or IEC 320 C20, 16-amp
(LI1420E-B74).
Output Receptacles:
LI 720E-B72:
8 IEC 320 C13.
LI 1420E-B74:
4 IEC 320 C13, 1 IEC 320-C19 (16-amp).