- 8 -
1. Use the supplied template to make
(4) holes in the upper part of the
cabinet. Secure top cabinet plate to
the cabinet by means (4) 4.2x15mm
wood screws. Refer Figure 8.
2. Only NON-DUCTED HOODS:
Install the flange to the cabinet by
means (3) wood screws (4.2 x 15
mm) supplied. Refer Figure 9.
3. FOR DECORATIVE FLUE
INSTALLATION:
Use the supplied template to make
(2) holes in the upper part of the
cabinet. Secure flue mounting
bracket to the cabinet by means (4)
4.2x15mm wood screws. Refer
Figure 10.
4. Select the correct cabinet spacers
according to the inside width of the
cabinet, refer Fig.12:
- for cabinets with an inside width of
34.5”, use 0.28” wide spacers.
- for cabinets with an inside width of
34.75”, use 0.40” wide spacers.
FIGURE 8
WOOD SCREWS
(4.2 x 15 mm)
TOP CABINET PLATE
FRAMING BEHIND WOOD
CROSS SUPPORT
WOOD SUPPORT
BEHIND DRYWALL
DRYWALL
FIGURE 11
0.28”
inside
cabinet
width
34.5”
0.4”
inside
cabinet
width
34.75”
FIGURE 12
CABINET
SPACERS
FIGURE 9
WOOD SCREWS
(4.2 x 15 mm)
FIGURE 10
WOOD SCREWS
(4.2 x 15 mm)