Installation Instructions for IDH Max 1300 Mortise Locks
BEST ACCESS SYSTEMS
A Division of Stanley Security Solutions, Inc
15
Installation Instructions for IDH Max 1300 Mortise Locks
Completing the installation at the door
15
Secure through-bolt trim and complete
connections
1 Position the inside and outside trim onto the door.
2
Making sure that the trim does not pinch the
wires
, secure the trim to the door—but do not
tighten. Use the combination mounting screw at the
top trim hole and the standard mounting screw at the
bottom trim hole.
Caution:
When routing the solenoid and sensor
wire harness, the sensor wires, and the solenoid
wires, make sure the wires are not routed across
any sharp edges or over any surface that could
damage their sleeving or wire insulation.
3 Make the solenoid connection and three sensor con-
nections, and place the wires into the inside trim.
Caution:
When making the sensor connections
and solenoid connection, make sure:
■
there are no loose wire connections where the
wires are inserted into the connectors
■
the connectors are firmly mated.
16
Install inside and outside knobs/levers
For both knobs and levers
Unscrew the inside spindle one (1) full turn to allow the
spindles to turn freely.
For knobs
1 From the outside of the door, insert the outside knob
and spindles assembly into the lockset.
Wire connection
Color
No.
of
wires
No.
of
pins
Solenoid
Yellow
2
3
RQE
Brown/
Orange
2
3
Latch status sensor
Purple
2
2
Door status sensor
White
2
2
Figure 15 Securing the through-bolt trim and
completing connections
Combination
mounting screw
Standard
mounting screw
Make these
connections.
Inside of door
Inside trim
Figure 16a Installing the knobs
Spindles
Set screw
Set screw
cap
Outside of door
Inside of door