Installation Instructions for IDH Max 1300 Mortise Locks
BEST ACCESS SYSTEMS
A Division of Stanley Security Solutions, Inc
5
Installation Instructions for IDH Max 1300 Mortise Locks
Preparing the door and door jamb
3
Mortise for lock case and faceplate
1 Mortise the edge of the door for the lock case.
Note:
The mortise cavity depth of 4 5/8
″
includes clear-
ance for wiring behind the mortise case.
2 Insert the lock in the mortise cavity.
3 Mark the outline of the lock faceplate.
4 Remove the lock. Mortise to fit the faceplate.
Figure 3
Mortising for the lock case and faceplate
Door
Lock faceplate
mortise
Lock case
mortise
Lock faceplate
Lock case