8
GB
English
!
The appliance must be installed by a qualified person
in compliance with the instructions provided.
!
Wear gloves when carrying out installation and
maintenance operations.
AIR VENT
(for ducting versions)
!
Prepare the hole and the air vent duct (150 mm
diameter).
!
Use a duct of the minimum indispensible length.
!
Use a duct with as few elbows as possible (maximum
elbow angle: 90°).
!
Avoid drastic changes in the duct cross-section.
!
Use a duct with an as smooth as possible inside.
!
The duct must be made of certified material.
!
Do not connect the hood to smoke exhaust ducts for
the products of combustion (boilers, fireplaces,
stoves, etc).
!
For the air vents comply with the provisions laid down
by the competent authorities.
In addition, the air must not be evacuated through a
hole in the wall unless specifically intended for this
purpose.
!
Fit air intakes in the room to prevent the hood from
creating a negative pressure in the room (which must
not exceed 0.04 mbar); if the hood is used at the
same time as non-electrical equipment (gas-, oil- and
charcoal-fired stoves, etc.) the exhaust gas may be
sucked in by the heat source.
FILTERING OR DUCTING VERSION ?
The hood may be in filtering or in ducting version.
Decide from the outset which type is to be installed.
For better efficiency, we recommend installing the hood
in the ducting version (if possible).
Ducting version
The hood purifies the air and evacuates it to the outside
through an exhaust duct (diameter 150 mm).
Filtering version
The hood purifies the air and recycles the clean air
back into the room.
CONTROLS
P1
P2
P3
P4
P5
P6
P7
P1:
Filter alarm reset
P2:
LED on/off - holding the button down you can
change the LED intensity to High or Low
Note: LED activation is displayed by P2 only when
the lift panel is completely open.
P3:
Motor on/off - 1st speed
P4:
2nd speed
P5:
3rd speed
P6:
4th speed
P7:
Lift panel up/down (during opening the panel can
be stopped at the desired height by pressing the
button a second time).
5' Timer function:
Holding the buttons P3, P4, P5 or P6 pressed down
(>2") the 5' Timer function is activated. When the time
has run out, the motor turns off and the lift closes. The
LEDs change from High to Low intensity. When the
function is active, the LED corresponding to the current
motor speed blinks.
Filter alarm display:
Grease filters: After 30h of motor operation, the LED of
the P1 button comes on for 30'' every time the motor
turns off.
Charcoal filter: After 120h of motor operation, the LED
of the P1 button blinks for 30'' every time the motor
turns off.
MAINTENANCE
!
Before cleaning or maintenance cut the power.
Cleaning the hood
WHEN TO CLEAN IT: clean it at least every 2 months
to prevent the risk of fire.
EXTERNAL CLEANING: use a cloth moistened in
lukewarm water and neutral detergent (for painted
hoods); use specific products for steel, copper or brass
hoods.
INTERNAL CLEANING: use a cloth (or brush) soaked
in denatured ethyl alcohol.
WHAT NOT TO DO: do not use abrasive or corrosive
products (e.g. metal sponges, brushes, too hard
brushes, very aggressive detergents, etc.)
Cleaning the grease filters
WHEN TO CLEAN IT: clean it at least every 2 months
to prevent the risk of fire.
HOW TO REMOVE THE FILTERS: push the catch
near the handle towards the rear of the hood and pull
the filter downwards
Summary of Contents for Lift
Page 2: ...2 ...
Page 3: ...3 2x 1x ø 15cm 8x 3 9x9 5mm 12x 4 2x15mm 4x 550 830 9 6 ...
Page 4: ...4 1 3 4 5 6 3 9 x 9 5 mm 4 2 x 15 mm 2 ...
Page 5: ...5 7 4 2 x 15 mm ...
Page 36: ...04308190 LIFT ...